HY2004 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – 120 WATTS Power Amplifier | |||
|
◁ |
ELECTRICAL / MECHANICAL
DETAILS AND DIMENSIONS
INSTALLATION NOTES
1. For normal usage and conditions the amplifier needs no supplementary heatsink.
2. It must be mounted to allow a vertical flow of air through the fins.
3. No input capacitor is required. An internal 100V working capacitor is fitted.
4. For loudspeaker protection it is recommended that a quickblow fuse is mounted
between the output and the speaker. The fuse rating specified has been calculated
to ensure fast rupture in the event of DC being presented to the speaker. It is
advised not to use a higher rated fuse.
5. The amplifier module is supplied in 4⦠mode. To set 8⦠mode simply make a link
between the two pads marked 'link'.
6. For 4⦠mode use a 3.15A quickblow fuse and for 8⦠a 2.5A quickblow fuse.
|