English
Language : 

BBA-322-A Datasheet, PDF (2/8 Pages) List of Unclassifed Manufacturers – GENERAL-PURPOSE BROADBAND RF AMPLIFIER DATA GUIDE
PERFORMANCE DATA – BBA-519-A
Parameters BBA-519-A
Supply Current
Input RF Power
Environmental Operating Temp.
Storage Temp.
Rating
120
+13
-40 to +85
-60 to 150
Unit
mA
dBm
°C
°C
ABSOLUTE MAXIMUM RATINGS
These ratings are intended to indicate the limits
past which device damage may occur.
Operation of the device at these limits is not
suggested or guaranteed.
HANDLING
CAUTION
ESD Sensitive Device
TYPICAL OPERATING PARAMETERS
All parameters measured @ 5.2 Volts, 25°C, -30dBm input
Parameters
BBA-519-A
Frequency Range
Gain
Gain Flatness
Noise Figure
Input VSWR
Output VSWR
Output IP3
Output P1dB
Reverse Isolation
Power Supply
Device Operating Voltage
Operating Current
Environmental
Rated Operating
Temperature
Typical
10 to 4000
18
17
15
13
12
±2
4.8
2.1:1
1.8:1
+33
+18.5
20
Units
MHz
dB
dB
dB
dB
dB
dB
dB
dBm
dBm
dB
4.8-5.2
5.2-12
60
VDC
VDC
mA
0-70
°C
Notes
T=25°C, Icc=65mA
Freq=100MHz
Freq=1000MHz
Freq=2000MHz
Freq=3000MHz
Freq=4000MHz
100MHz to 2000MHz
Freq=2000MHz
In a 50Ωsystem, DC to 4000MHz
In a 50Ωsystem, DC to 4000MHz
Freq=1000MHz±50KHz, PTONE=-10dBm
Freq=1000MHz
Freq=2000MHz
VCC regulated between 4.8 and 5.2VDC
VCC Range using appropriate current limiting
resistor inline with VCC
@5VDC
Page 2