English
Language : 

60N035 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – N-Channel Field Effect Transistor
60N035
Electrical Characteristics ( TC = 25°C unless otherwise specified)
Symbol
Parameter
Conditions
Min
OFF CHARACTERSTICS
BVDSS
Drain source breakdown
voltage
VGS=0V, ID=250µA
30
IDSS
Zero Gate Voltage Drain
Current
VDS=24V
VGS=0V
IGBLF
IGBLR
Gate-Body Leakage Forward VGS=20V VDS=0V
Gate-Body Leakage Reverse VGS=20V VDS=0V
ON CHARACTERSTICS
VGS
Gate Threshold Voltage
VDS=VGS
ID=250µA
1
RDS(ON)
Static Drain Voltage
VGS=10V, ID=26A
VCS=4.5V, IO=21A
ID(ON)
ON-State Drain Current
VGS=10V
60
gfs
Forward Tran conductance
DYNAMIC CHARACTRISTICS
CISS
COSS
CRSS
Input Capacitance
Output Capacitance
Reverse Tras. Capacitance
VDS= 15V, VGS=0V
F=1.0 MHZ
SWITCHING CHARACTERSTICS
tD(ON)
tr
td(off)
tF
Turn-ON Delay Time
Turn-ON Rise Time
Turn-OFF Delay Time
Turn-OFF Fall Time
VDD=15V
ID=52A, VDS=10V
RGEN=25Ω
SOURCE DRAIN DIODE CHRACTERISTICS
IS
VDS (note)
Maxim Continuous Drain source Diode Forward Current
Drain Source Diode
VGS=0V
Forward Votlage
IS=26A
THERMAI CHRACTERISTICS
RJC
Thermal Resistance, Junction to Case
RJC
Thermal Resistance, Junction to Ambient
Typ
0.014
Max Units
V
10
µA
100
nA
-100
nA
3
V
0.015
0.025 Ω
A
1500
pF
700
pF
300
pF
60
200
50
nS
120
60
A
1.35
V
2.5
°C/W
62.5 °C/W
Note: Pulse Test: Pulse With≤ 300 µS, Duty Cycle ≤ 2.0%
Advance Information- These data sheets contain descriptions of products that are in development. The specifications are based on the engineering calculations,
computer simulations and/ or initial prototype evaluation.
Preliminary Information- These data sheets contain minimum and maximum specifications that are based on the initial device characterizations. These limits are
subject to change upon the completion of the full characterization over the specified temperature and supply voltage ranges.
The application circuit examples are only to explain the representative applications of the devices and are not intended to guarantee any circuit
design or permit any industrial property right to other rights to execute. Bay Linear takes no responsibility for any problems related to any
industrial property right resulting from the use of the contents shown in the data book. Typical parameters can and do vary in different
applications. Customer’s technical experts must validate all operating parameters including “ Typical” for each customer application.
LIFE SUPPORT AND NUCLEAR POLICY
Bay Linear products are not authorized for and should not be used within life support systems which are intended for surgical
implants into the body to support or sustain life, in aircraft, space equipment, submarine, or nuclear facility applications without
the specific written consent of Bay Linear President.
Bay Linear, Inc 2478 Armstrong Street, Livermore, CA 94550 Tel: (925) 989-7144, Fax: (925) 940-9556
www.baylinear.com