5.8 ESD Test Results
Test Description: ESD Testing was performed on a Zapmaster system using the
Human-Body-Model (HBM) and Machine-Model (MM), according to MIL-STD 883 and
EIAJ IC-121 respectively.
• Human-Body-Model stresses devices by sudden application of a high voltage
supplied by a 100pF capacitor through 1.5k-ohm resistance.
• Machine-Model stresses devices by sudden application of a high voltage supplied
by a 200pF capacitor through very low (0 ohm) resistance.
Test Circuit & Condition
- Zap Interval: 1 second
- Number of Zaps: 3 positive and 3 negative at room temperature
- Criteria: I-V Curve Tracing
Model
HBM
MM
Table 5.10 ESD Data
Mode
S/S
Target
Vdd, Vss, I/C
15
6000V
Vdd, Vss, I/C
15
200V
Results
PASS
PASS