English
Language : 

V20W Datasheet, PDF (16/24 Pages) List of Unclassifed Manufacturers – PIEZOELECTRIC ENERGY HARVESTERS
APPLICATIONS INFORMATION - SWITCHED CAPACITOR BOOST CIRCUIT
these cases, the application can use Vout as an
interrupt source in addition to power source, with a
rising or falling edge triggering the desired action.
Typical Results
The following are measured results using the circuit
shown in a typical configuration.
Discharge Interval vs. Acceleration
Volture V20W @ 60Hz, 100uF
10 3
10 2
10 1
10 0
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Acceleration (g)
Figure 2: Discharge Interval vs. Acceleration, measured
results using configuration shown
Averaged Power Output vs. Acceleration
Volture V20W @ 60Hz
90
80
70
60
50
40
30
20
10
0
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Acceleration (g)
Figure 4: Averaged Power Output vs. Acceleration
Usable Bandwidth vs. Acceleration
Volture V20W
60
50
40
30
20
10
0
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2
Acceleration (g)
Figure 3: Usable Bandwidth vs. Acceleration at 60Hz center
frequency. Usable bandwidth refers to the frequency range
over which the setup produced voltages exceeding the
circuit’s turn-on threshold (2.4V), producing output pulses.
REVISION N0. 002 REVISION DATE: 01-23-2013