English
Language : 

4245AB51K00650 Datasheet, PDF (13/20 Pages) List of Unclassifed Manufacturers – Metallized Conductive Products
FA B R I C - O V E R - F O A M
I/O SELECTION GUIDE
The following pages show examples of standard I/O gaskets used in computer and telecommunication applications. If you have
different requirements, the Engineering Department will design gaskets to the specifications you supply. Laird Technologies will
design your I/O from a fully detailed print, drawing file, or the actual panel to which the gasket is to be applied.
I/O Gasket Tolerances
Height tolerance
± .020" (±0.5mm)
Width tolerance
± .020" (±0.5mm)
Length tolerance
± .020" (±0.5mm)
Cutout tolerance
± .020" (±0.5mm)
If different tolerances are required, please consult Engineering. See page 26 for contact information.
ERL
1
PSA Tape
3
4
2
Basic I/O Gasket Design
1. Space between required cutouts should match or exceed 0.060" (1,5mm).
2. D istance from the edge of a cutout should be at least 0.060" (1,5mm)
from the edge of the gasket. In most cases, a slot can be used in place
of a hole that is positioned too close to the gasket edge.
3. All cutouts and locations are designed customer specifications.
4. P ressure Sensitive Adhesive (PSA) and Extended Release Liner (ERL) can be
applied in parallel with the long edge of the gasket.
The recommended operating compression for Fabric-Over-Foam EMI gaskets
will vary depending on the shape and size of the particular gasket. Typically,
I/O gaskets should be compressed between 30% and 50% of the foam height.
13
www.lairdtech.com