CLR79 Datasheet, PDF (10/12 Pages) List of Unclassifed Manufacturers – Commercial Types TAT for CLR79 and TAX for CLR81 | |||
|
◁ |
Wet
Tantalum
-
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Performance Testing
Seal: MIL-STD-202 - Method 112
⢠Conditions A, or D, and C
Specified Pulse Shock Test: MIL-STD-202 - Method 213 includes the following:
⢠Condition D (500gâs)
⢠Mount the capacitor by its body securely on a fixture taking special care not to squeeze the leads.
⢠While testing apply DC rated voltage. Record whether open or short circuiting, arching, or intermittent contact
occurs. Use detecting equipment capable of detecting a disruption at a period of time up to 0.5 ms.
⢠At the conclusion of testing examine the capacitors for evidence of arcing, breakdown, or mechanical damage.
Thermal Shock: MIL-STD-202 â Method 107, Condition A (with step 3 at +125°C).
In accordance with MIL-PRF-39006, the following shall apply:.
⢠Take measurements before and after cycling.
⢠Take measurements at 15-minute intervals at 300 cycles (Group C).
⢠Take final measurements at room temperature.
High Frequency Vibration: MIL-STD-202 - Method 204 includes the following:
⢠Condition H (80gâs)
⢠Mount the capacitor body securely on a fixture with the leads firmly supported.
⢠Apply DC rated voltage while measuring specific electrical load conditions.
⢠The vibration duration is 4 hours in two perpendicular directions for an overall time of 8 hours.
⢠Take measurements during the last cycle vibration to determine open, short-circuiting or intermittent operation.
Use detecting equipment capable of detecting a disruption at a period of time of 0.5ms or greater. Assess the
units for mechanical damage and test for these electrical requirements:.
o DC Leakage â Not greater than 1.25 initial limit
o Capacitance â No change greater than ±5% of the initial limit
o DF â Not greater than 1.15 of initial limit
Random Vibration: MIL-STD-202 â Method 214
⢠Test condition II-K (51 gâs)
Salt atmosphere: MIL-STD-202 â Method 101
⢠Condition B 48 hours
Solderability: MIL-STD-202 â Method 208
⢠Test both terminations with the insertion depth of flux and solder within .062" of welded seam.
Lead Terminal Strength:
⢠Pull Test: MIL-STD-202 â Method 211, condition A
⢠Wire-lead bend: Per MIL-PRF-39006.
⢠During the test securely clamp the capacitor body. Apply a force of 3 pounds or 1.4 kg for 30 seconds.
Moisture resistance: MIL-STD-202- Method 106, which includes the following:
⢠Mount the capacitor body securely on a fixture taking special care not to squeeze the leads.
⢠Apply 6 volts, polarizing and load voltage
⢠At the time of the capacitors complete their final cycle remove them from the humidity chamber and measure
per MIL-PRF-30006 for DC Leakage, dissipation factor, and capacitance.
o DCL: 125% (Maximum) of +25°C value of standard ratings table
o âCap: Within ±8% of initial measurement
o DF: 115% (maximum) of initial requirement
Cornell Dubilier ⢠140 Technology Place ⢠Liberty, SC 29657 ⢠Phone: (864)843-2277 ⢠Fax: (864)843-3800 ⢠www.cde.com
|
▷ |