English
Language : 

FAA01DM24 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – Timers Delay on Operate
Timers
Delay on Operate
Types FAA01, FAA08
• Time range 0.05 s to 300 h
• Knob selection of time range
• Knob adjustable time setting
• Knob selection of operating mode (4 functions):
A - delay on operate
B2 - symmetrical recycler ON first
E - interval
J - one shot
• Automatic start
• Repeatability: ±0.3% on full scale
• Output: 5 A DPDT relay
• 48 x 48 mm housing for front panel mounting
• 8 or 11 pin sockets
• LED indication for relay status and power supply ON
Product Description
Ordering Key
Delay on operate timer with
4 functions and selectable
time ranges from 0.05 sec-
onds to 300 hours.
Housing 48 x 48 mm for
front panel mounting and on
8-pin or 11-pin socket.
Housing
Function
Type
Item number
Output
Power supply
Type Selection
Mounting
Output
Front or socket
Front or socket
DPDT
DPDT
Plug
11-pin
8-pin
Supply: 100 to 240 VAC
FAA01DM24
FAA08DM24
FAA 01 D M24
Time Specifications
Output Specifications
Time ranges
Selectable by front knob
Time unit
sec min hrs
1.2
0.05 to 1.2
Full scale
3
setting
12
0.125 to 3
0.5 to 12
30
1.25 to 30
10h
0.5 to 12
1.25 to 3
5 to 120
12.5 to 300
Repeatability
Setting accuracy
Voltage drift
Temperature drift
Reset
Power supply interruption
Pulse width
±0.3% on full scale
(±10 ms max in the range
of 1.2 s)
±5% on full scale ±50 ms
±0.5% on full scale
(±10 ms max in the range of
1.2 s)
±2% on full scale
(±10 ms in the range
of 1.2 s)
>100 ms
>50 ms
Output
Output insulation resistance
Contact Ratings (AgCdO12)
Resistive loads
AC 1
Mechanical life
Electrical life
Operating frequency
DPDT relay
> 100 MΩ (at 500 VDC)
µ
5 A @ 250 VAC / 30 VDC
≥ 1 x 107 operations
≥ 1 x 105 operations
(5 A at 250 VAC, cos ϕ = 1,
1.8 x 103 operations/h)
< 1800 operations/h
Supply Specifications
Power Supply
Rated operational voltage
throuhgt terminals:
(FAA01DM24)
2, 10
(FAA08DM24)
2, 7
Power consumption
Rated operational power
Overvoltage cat II
(IEC 60947-1)
100 to 240 VAC +10%-15%
50 / 60 Hz
100 to 240 VAC +10%-15%
50 / 60 Hz
10VA @ 240 VAC, (50 Hz)
Specifications are subject to change without notice (26.07.05)