English
Language : 

SVS20 Datasheet, PDF (1/8 Pages) ETAL Group – Systematic integration of protection and distribution functions
Power Distribution System SVS20
Description
The power distribution system SVS20 for rail mounting distributes
the current supplied by a DC 24 V switch-mode power supply to 8
channels and selectively protects the connected loads by means
of the inserted circuit breakers. With a max. load current of 8 A per
channel and a max. total current of 40 A the SVS20 provides ease of
wiring in short-circuit limited DC 24 V applications. Eight protected
“L+” load outputs per channel and 35 minus terminals help to reduce
wiring time significantly.
Suitable for the following circuit breaker types:
Electronic circuit breaker
ESS20-003..
Electronic circuit protector
ESX10-103..
Features and benefits
Technical data (Tamb = 25 C, UB = DC 24 V)
l Systematic integration of protection and distribution functions
l Power distribution and selective protection of DC 24 V load
Application
circuits all-in-one
l Clear distribution and wiring concept
Modular power distribution system for short circuit limited DC 24 V
applications
l Significant reduction of wiring time
l Ease of planning, design and installation
l Ease of maintenance, diagnostics and system extension
Supply
Voltage rating
DC 24 V (18...32 V)
l Compact power distribution for compact control cabinets
l Additional integral minus terminals
l External loop-in facilities between load output terminal (L)
and (1) per channel
l Signal contact can be arranged in groups:
F1…F4 = gr. 1, F5…F8 = gr. 2 possible
Total current
Terminals
max. 40 A
DC 24 V (+) = X21 + / + / +
DC 24 V (-) = X21 - / - / -
3 x 2 screwless terminals max. 10 mm2, for
power supplies
loop-through integral, for wiring
max. cable cross section
Ordering information
without/ with wire
end ferrule
0,25 – 10 mm2
stripping length 12 mm
Type
SVS20 Power distribution system for ESS20-003, ESX10-103
l For short-circuit limited DC 24 V applications
l Max. 40 A continuous load
l One integral circuit breaker (CB1): overcurrent protection
for split-group and group signalling, LED flashing red
after trip of CB1
F-positions
8 positions for circuit breakers, prepared for types ESS20-003,
ESX10-103
U1-potential / F1...F8 = terminals X1...X8
Plug jumper SB-11-P1-01-1-1A into free positions
(order separately, see accessories)
l Including 8 insulated wire bridges Y 303 881 08 between
L and 1 fitted
l Including 1 insulated wire bridge Y 303 881 08
Load outputs per channel
Voltage rating
DC 24 V (18…32 V)
l Accessories: jumpers SB-11-P1-01-1-1A
Current
max. 8 A per terminal block / position 1)
(for free channels), order separately
Version, max. number of circuit breakers
on the system
08 8 circuit breakers (F1...F8)
Fitting variant, load output / minus and signalling
Terminals
10 x L/1/2/3/4//5/6/7/8/9 protected per
position F1...F8
led out to terminals X1...X8
screwless terminals max. 2.5 mm2
terminals
B10 Standard: completely fitted with plug-in type
screwless terminals (max. 2,5mm2, without
wire end ferrule)
External loop-in facilities between load
output terminal (L) and (1) per channel
6
delivery status: load output terminal (L)
and (1), bridged with “jumper insulated“
Minus terminals
K01 35 minus terminals
Minus terminals
Special version
Voltage rating
DC 24 V (18…32 V)
SB01 with marked terminals
supply terminals +/+/+/-/-/-
Current
max. 8 A per terminal block
load output terminals
Terminals
5-pole terminals X22…X28
L/1/2/3/4//5/6/7/8/9
(total 35 minus terminals)
minus- / signal terminals 1/2/3/4/5
screwless terminals max. 2.5 mm2
max. (cable cross section)
SVS20 - 08 - B10-K01-SB01 ordering example
without/with wire end ferrule 0.25 – 10 mm2
stripped length
10 mm
Accessories: jumper and wire bridge see page “Accessories”
1) When connected in series and mounted side-by-side, circuit breakers type ESS20, ESX10,
rated 10 A can only carry 80 % rated load.