English
Language : 

PTB20193 Datasheet, PDF (3/3 Pages) Ericsson – 60 Watts, 1.8-1.9 GHz Cellular Radio RF Power Transistor
e
Typical Performance
Gain vs. Frequency
(as measured in a broadband circuit)
9.0
8.5
8.0
7.5
7.0
1800
VCC = 26 V
ICQ = 150 mA
Pout =15 W
1820
1840
1860
1880
Frequency (MHz)
1900
PTB 20193
Efficiency vs. Output Power
60
50
40
30
20
VCC = 26 V
ICQ = 150 mA
10
f = 1.9 GHz
0
20 25 30 35 40 45 50 55 60 65
Output Power (Watts)
Intermodulation Distortion vs. Power Output
-26
-28
VCC = 26 V
ICQ = 150 mA
-30
f1 = 1.899 GHz
-32
f2 = 1.900 GHz
-34
-36
-38
-40
0
10
20
30
40
50
60
Output Power (Watts-PEP)
Ericsson Components
RF Power Products
675 Jarvis Drive
Morgan Hill, CA 95037 USA
Telephone: 408-778-9434
5/19/98
1-877-GOLDMOS
(1-877-465-3667)
e-mail: rfpower@ericsson.com
www.ericsson.com/rfpower
3
Specifications subject to change without notice.
LF
© 1996 Ericsson Inc.
EUS/KR 1301-PTB 20193 Uen Rev. A 09-28-98