S1D15714 Datasheet, PDF (44/65 Pages) Epson Company – a single chip MLS driver | |||
|
◁ |
S1D15714 Series
Table 7.1 Table of commands in S1D15714 Series series
Command code
Command
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
Function
(1) Display ON/OFF
0 1 0 1 0 1 0 1 1 1 0 LCD display ON/OFF control.
1 0: OFF, 1: ON
(2) Display Normal
/Reverse
0 1 0 1 0 1 0 0 1 1 0 LCD display normal/reverse
1 0: Normal, 1: Reverse
(3) Display All Lighting
ON/OFF
0 1 0 1 0 1 0 0 1 0 0 Display All Lighting
1 0: Normal display, 1: All ON
(4) Common Output
Status Select
0 1 0 1 1 0 0 0 1 0 0 Selects COM output scan direction.
1 0: Normal, 1: Reverse
(5) Display Start Line Set 0 1 0 1 0 0 0 1 0 1 0 Sets display start line.
0 1 0 * * Display start line address
(6) Page Address Set
0 1 0 1 0 1 1 0 0 0 1 Sets the display RAM page address.
**
Page address
(7) Column Address Set 0 1 0 0 0 0 1 Higher column Higher 4 bits of column address in
Higher bits
address
Display RAM are set.
Column Address Set 0 1 0 0 0 0 0 Lower column Lower 4 bits of column address in
Lower bits
address
Display RAM are set.
(8) Display Data Write
11 0
Writes data
Writes data to the display RAM.
(9) Display Data Read
10 1
Reads data
Reads data to the display RAM.
(10) Display Data Input
Direction Select
0 1 0 1 0 0 0 0 1 0 0 Display RAM data input direction
1 0: Column direction 1: Page direction
(11) Column Address Set
Direction
01
0 1 0 10 0 0 00
1
Compatible with display RAM
address SEG output
0: Normal 1: Reverse
(12) n-line inversion Drive 0 1 0 0 0 1 1 Invert line count Line invert drive.
Register Set
Sets the line count.
(13) n-line ON/OFF
0 1 0 1 1 1 0 0 1 0 0 Resets the line invert drive.
0: n-line OFF 1: n-line ON
(14) Duty Set Command 0 1 0 0 1 1 0 1 1 0 1 2 byte command
Duty Set Static spot set 0 1 0 * * Static spot (block)
(15) Read Modify Write
01
0 1 1 10 0 0 00
Increments the column address.
Increments +1 in the write mode.
Does not increment in the read mode.
(16) End
0 1 0 1 1 1 0 1 1 1 0 Resets read modify write functions.
(17) Built-in Oscillator
Circuit ON/OFF
0 1 0 1 0 1 0 1 0 1 0 Built-in oscillator circuit operation
1 0: OFF, 1: ON
(18) Built-in Oscillator
0 1 0 0 1 1 1 Frequency
Circuit Frequency Select
(19) Power Control Set
0 1 0 0 0 1 0 1 Operation state Selects built-in power supply
operation state.
(20) Liquid Crystal Drive
Voltage Select
(21) LCD bias change
01
01
0 0 0 1 0 0 V3 range
0 1 0 1 0 0 0 bias
Bias ratio select
(22) Electronic Volume
Mode Set
Electronic Volume
Register Set
01
01
0 1 0 00 0 0 01
0 * Electronic volume
V3 output voltage is set to the
electronic volume register. 128 states
(23) Discharge ON/OFF
01
0 1 1 10 1 0 10
1
Discharges Power supply circuit
connection capacitor.
0: OFF (normal), 1: ON
(24) Power Save ON/OFF 0 1 0 1 0 1 0 1 0 0 0 Power Save 0: OFF, 1: ON
1
(25) Temperature
Gradient Select
0 1 0 0 1 0 0 1 Temperature gradient Sets to 8 steps.
(26) Stator Read
0 1 0 1 0 0 0 1 1 1 0 Issues the temperature gradient
0 0 1 * * * * *Temperature gradient select bit. * : denote invalid bits.
(27) Reset
01
0 1 1 10 0 0 10
Resets the column, page and
address registers.Resets the read
modify write function.
(28) Temperature
Sensor ON/OFF
0 1 0 0 1 1 0 1 0 0 0 Temperature sensor
0 : OFF (normal), 1 : ON
(29) MLS Drive Select
(2-byte command)
0 1 0 1 1 1 0 0 1 1 1 Mode Set
0 1 0 * * * 0 MLS 0 1 1 MLS 0 : Dispersion, 1: Non-dispersion
(30) NOP
0 1 0 1 1 1 0 0 0 1 1 Non-operation command
Rev. 1.0
EPSON
41
|
▷ |