English
Language : 

G1540 Datasheet, PDF (3/21 Pages) Global Mixed-mode Technology Inc – Low Power Quadruple Operational Amplifiers
Temperature measurement
Glass-encapsulated sensors
B57540G1
G1540
Electrical specification and ordering codes
R25
Ω
5k
5k
10 k
10 k
10 k
10 k
50 k
50 k
100 k
100 k
No. of R/T B25/85
characteristic K
8324
8324
7003
7003
8307
8307
7002
7002
8304
8304
3483
3483
3612
3612
3478
3478
3973
3973
4072
4072
B0/100
K
3456
3456
3586
3586
3450
3450
3944
3944
4036
4036
+ = Resistance tolerance
F = ±1%
G = ±2%
H = ±3%
The last three digits of the ordering code denote:
000 and 005 = dumet wires
002 and 007 = nickel-plated wires
B25/100
K
3497 ±1%
3497 ±1%
3625 ±1%
3625 ±1%
3492 ±1%
3492 ±1%
3988 ±1%
3988 ±1%
4092 ±1%
4092 ±1%
Ordering code
B57540G1502+000
B57540G1502+002
B57540G1103+005
B57540G1103+007
B57540G1103+000
B57540G1103+002
B57540G1503+005
B57540G1503+007
B57540G1104+000
B57540G1104+002
Reliability data
Test
Storage in
dry heat
Storage in damp
heat, steady state
Rapid temperature
cycling
Standard Test conditions
IEC
60068-2-2
IEC
60068-2-67
IEC
60068-2-14
Storage at upper
category temperature
T: 250 °C
t: 1000 h
Temperature of air: 85 °C
Relative humidity of air: 85%
Duration: 1000 h
Lower test temperature: 55 °C
Upper test temperature: 200 °C
Number of cycles: 1000
∆R25/R25
(typical)
< 3%
< 2%
< 2%
Remarks
No visible
damage
No visible
damage
No visible
damage
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 21