EN25B16 Datasheet, PDF (9/36 Pages) Eon Silicon Solution Inc. – 16 Mbit Serial Flash Memory with Boot and Parameter Sectors
EN25B16
Table 3b. Protected Area Sizes- Top Boot Sector Organization
Status Register
Content
BP2 BP1 BP0
Bit Bit Bit
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Protect Sectors
None
Sector 35
Sector 34 to 35
Sector 33 to 35
Sector 32 to 35
Sector 31 to 35
Sector 16 to 35
All
Memory Content
Addresses
Density(KB)
None
1FF000h-1FFFFFh
1FE000h-1FFFFFh
1FC000h-1FFFFFh
1F8000h-1FFFFFh
1F0000h-1FFFFFh
100000h-1FFFFFh
000000h-1FFFFFh
None
4KB
8KB
16KB
32KB
64KB
1024KB
2048KB
Portion
None
Upper 1/512
Upper 1/256
Upper 1/128
Upper 1/64
Upper 1/32
Upper 1/2
All
Hold Function
The Hold (HOLD) signal is used to pause any serial communications with the device without resetting the
clocking sequence. However, taking this signal Low does not terminate any Write Status Register,
Program or Erase cycle that is currently in progress.
To enter the Hold condition, the device must be selected, with Chip Select (CS#) Low. The Hold condition
starts on the falling edge of the Hold (HOLD) signal, provided that this coincides with Serial Clock (CLK)
being Low (as shown in Figure 4.).
The Hold condition ends on the rising edge of the Hold (HOLD) signal, provided that this coincides with
Serial Clock (CLK) being Low.
If the falling edge does not coincide with Serial Clock (CLK) being Low, the Hold condition starts after
Serial Clock (CLK) next goes Low. Similarly, if the rising edge does not coincide with Serial Clock (CLK)
being Low, the Hold condition ends after Serial Clock (CLK) next goes Low. (This is shown in Figure 4.).
During the Hold condition, the Serial Data Output (DO) is high impedance, and Serial Data Input (DI) and
Serial Clock (CLK) are Don’t Care.
Normally, the device is kept selected, with Chip Select (CS#) driven Low, for the whole duration of the
Hold condition. This is to ensure that the state of the internal logic remains unchanged from the moment
of entering the Hold condition.
If Chip Select (CS#) goes High while the device is in the Hold condition, this has the effect of resetting the
internal logic of the device. To restart communication with the device, it is necessary to drive Hold (HOLD)
High, and then to drive Chip Select (CS#) Low. This prevents the device from going back to the Hold
condition.
Figure 4. Hold Condition Waveform
This Data Sheet may be revised by subsequent versions
9
or modifications due to changes in technical specifications.
©2004 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. C, Issue Date: 2006/12/22