English
Language : 

EN25LF05 Datasheet, PDF (8/30 Pages) Eon Silicon Solution Inc. – 512 Kbit Serial Flash Memory with 4Kbytes Uniform Sector
EN25LF05
In the case of multi-byte commands of Page Program (PP), and Release from Deep Power
Down (RES ) minimum number of bytes specified has to be given, without which, the
command will be ignored.
In the case of Page Program, if the number of byte after the command is less than 4 (at least
1 data byte), it will be ignored too. In the case of SE and BE, exact 24-bit address is a must,
any less or more will cause the command to be ignored.
All attempts to access the memory array during a Write Status Register cycle, Program cycle or
Erase cycle are ignored, and the internal Write Status Register cycle, Program cycle or Erase cycle
continues unaffected.
Table 4. Instruction Set
Instruction Name
Byte 1
Code
Byte 2
Byte 3
Byte 4 Byte 5 Byte 6
n-Bytes
Write Enable
06h
Write Disable / Exit
OTP mode
04h
Read Status
Register
05h
Write Status
Register
01h
Read Data
03h
Fast Read
0Bh
Page Program
02h
(S7-S0)(1)
S7-S0
A23-A16
A23-A16
A23-A16
A15-A8
A15-A8
A15-A8
continuous
(2)
A7-A0
A7-A0
A7-A0
(D7-D0)
dummy
D7-D0
(Next byte)
(D7-D0)
Next byte
continuous
(Next Byte)
continuous
continuous
Sector Erase
20h
A23-A16 A15-A8
A7-A0
Block Erase
D8h/ 52h A23-A16 A15-A8
A7-A0
Chip Erase
C7h/ 60h
Deep Power-down B9h
Release from Deep
(4)
Power-down, and
dummy
dummy dummy (ID7-ID0)
read Device ID
ABh
Release from Deep
Power-down
Manufacturer/
Device ID
90h
dummy
dummy
00h(5) (M7-M0) (ID7-ID0)
Read Identification 9Fh
(M7-M0) (ID15-ID8) (ID7-ID0)
Enter OTP mode
3Ah
Notes:
1. Data bytes are shifted with Most Significant Bit first. Byte fields with data in parenthesis “( )” indicate data being read from
the device on the DO pin.
2. The Status Register contents will repeat continuously until CS# terminate the instruction.
3. All sectors may use any address within the sector.
4. The Device ID will repeat continuously until CS# terminate the instruction.
5. The Manufacturer ID and Device ID bytes will repeat continuously until CS# terminate the instruction.
00h on Byte 4 starts with MID and alternate with DID, 01h on Byte 4 starts with DID and alternate with MID.
Table 5. Manufacturer and Device Identification
OP Code (M7-M0)
(ID15-ID0)
(ID7-ID0)
ABh
90h
1Ch
9Fh
1Ch
05h
05h
3110h
This Data Sheet may be revised by subsequent versions
8
or modifications due to changes in technical specifications.
©2004 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. C, Issue Date: 2008/06/23