English
Language : 

TLP150-M Datasheet, PDF (3/4 Pages) Emerson Network Power – 150 W on main channel with only 200 LFM
Embedded Power for
Business-Critical Continuity
Ordering Information
Output Voltage
Min
12 V
0A
24 V
0A
Output Current
Max (free air)(1,4) Max (forced air)(2,4)
8.4 A
12.5A
4.2A
6.3 A
Ripple
120 mV
240 mV
Total Regulation Model Numbers
±3.0%
±3.0%
TLP150N-99S12J
TLP150N-99S24J
Rev.12.23.08_140
TLP150-M Series
 of 4
Notes
1 Free air convection. Maximum continuous output power not to exceed 100 W.Refer to
Figure 1 for the derating curve.
DERATING CURVE Output Power (Watts)
2 200 LFM forced air cooling from the ac input side. Maximum continuous output power not
to exceed 150 W.
3 Figure is peak-to-peak for room temperature rating. Output noise measurements are made
150 W
across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF tantalum
200 LFM (1.0 m/s)
capacitor and a 0.1 µF ceramic capacitor.
FORCED AIR COOLING
4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making
thermal measurements. For optimum reliability no part of the heatsink should exceed 115
100 W
°C and no semi-conductor case temperature should exceed 120 °C.
5 No external filtering required during conducted emissions testing but some applications
may require additional filtering to achieve system compliance.Compliance with radiated
EMI specifications may require mounting in a suitable enclosure.
NATURAL CONVECTION COOLING
6 This product is only for inclusion by professional installers within other equipment and
must not be operated as a stand alone product.
7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G.
8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output
and/or remote ON/OFF control is required
0W
e.g. TLP150N-99S12FJ.
0 C 10 C 20 C 30 C 40 C 50 C 60 C
9 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is
available whenever ac input is present, regardless of remote ON/OFF signal status.
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.TSE RoHS 5/6
Figure 1: Derating Curve
(non Pb-free) compliant versions may be available on special request, please contact your
local sales representative for details.­
11 NOTICE: Some models do not support all options. Please contact your local Emerson
representative or use the on-line model number search tool at
http://www.powerconversion.com to find a suitable alternative..
75 W
50 W
70 C
Outline Dimensions
5.000 (127.00)
4.550 (115.57)
J3
J1 1
Neutral
Live
J2
Ground/Earth
ø0.156 (4 Places)
Dimensions in Inches (mm)
1
FAN 1
J4
1
R88
0.225 (5.72)
Figure 2: Mechanical Drawing
Trimmer Adjust
Output Voltage
1
J301
Total Height
1.250 (31.75)