English
Language : 

IBC60 Datasheet, PDF (3/4 Pages) Emerson Network Power – Fixed Ratio 2nd Generation IBC
Embedded Power for
Business-Critical Continuity
Ordering Information
Ordering Information
Output
Power
(Max.)
642 W
Input Output
Voltage Voltage
38-55 Vdc 9.6 V
Output
Current
(min.)
0A
Output
Current
max.)
60 A
Efficiency
(typ)
97%
Set Point
Accuracy
--
Regulation
Line %
32.5%
Load %
2.5%
Rev. 02.11.09_162
Quarter-Brick Fixed IBC60
 of 4
Model Numbers
IBC60AQN4896J
Part Number System with Options
IBC 60A Q N4896-RENJ
Product Family
IBC = Intermediate Bus Converter
2nd Generation
Rated Output Current
60 A = 60 Amps at 48 V
Form Factor
Q = Quarter-Brick
Input Voltage Type
T = Narrow Input Fixed Ratio
S = Narrow Input Semi-reguated
N = Narrow Telecom Fixed Ratio
W = Wide Telecom Semi-reguated
RoHS Compliance
J = Pb-free (RoHS 6/6 compliant)
Pin Length Options
Blank = 0.188 ” (4.78 mm)
N = 0.145 ” (3.68 mm)
K = 0.110 ” (2.79 mm)
Package, Body Height
E = Open-Frame, 0.48 in (12.2 mm)
Remote ON/OFF Logic
Blank = Positive
R = Negative (See Note 6)
Output Voltage
96 = 9.6 V
Input Voltage
48 = 48 V
Notes
1 Recommended input fusing is a 20 A HRC 250 V rated fuse.
2 Measured with external filter.See Application Note 209 for details.
3 Start-up into resistive load.
4 Peak to peak measured without external Pi filter.Significant reduction
possible with external filter.See Application Note 209 for details.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Active-low remote ON/OFF option is also available.Please add the suffix ‘-R’
to the part number, e.g. IBC60AQN4896-REJ.
7 Maximum output power at maximum input voltage.
8 Efficiency at 100% maximum output voltage.
9 After an input overvoltage latch off, the input voltage must be returned to 55
V or lower for unit to restart.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.