IBC60 Datasheet, PDF (1/4 Pages) Emerson Network Power – Fixed Ratio 2nd Generation IBC | |||
|
Embedded Power for
Business-Critical Continuity
Quarter-Brick
Series
Fixed Ratio 2nd
Generation IBC
Total Power: 600W
Input Voltage: 38 - 55VDC
Rev. 02.11.09_162
Quarter-Brick Fixed IBC60
of 4
Special Features
⢠48 V input with isolated 9.6 V
output
⢠Ultra-high efficiency, 97%
⢠Unprecedented usable output
power levels
⢠High power density open-frame
technology
⢠Wide operating ambient
temperature range
⢠DOSA quarter-brick high
current footprint and pinout
⢠Low profile, 0.48â (12.2 mm)
⢠Meets basic insulation
requirements of EN60950-1
⢠Remote ON/OFF and
overtemperature protection
⢠RoHSâcompliant
⢠2 Year Warranty
Safety
⢠UL/cUL : CAN/CSA 22.2
No. 60950-1 : UL60950-1
File No. E135734
⢠VDE File No. 10401-3336-0206
Licence No. 40012752
Electrical Specifications
Input
Input voltage raÂnge:
Input current:
Input current (max.):
Input reflected ripple:
Remote ON/OFF
Logic compatibility
ON
OFF:
Undervoltage lockout:
Start-up time:
(See Note 3)
Remote OFF
(See Note 1)
(See Note 4)
Power up
Power down
Power up
Remote ON/OFF
38-55 Vdc
6.5 mA typ.
13 A max. @ lo max.
and Vin = min. rated
1200 mA (pk-pk)
35 mA rms
(See Note 6)
Open collector ref. to -Input
> 2.4 Vdc
< 0.4 Vdc
34.5 V
33 V
11rms
2 rms
Output
Line regulation:
Load regulation:
Low line to high line
Full load to min. load
See table
See Table
Total error band:
Vin = 38 V to 55 V
(including setpoint, line, load and temperature)
7.0 - 11.0 Vdc
Minimum load:
Overshoot:
0A
At turn-on and turn-off None
Undershoot:
None
Ripple and Noise:
5-20 MHz
(See Note 2)
100 mV pk-pk typ.
20 mV rms typ.