English
Language : 

BXA3 Datasheet, PDF (3/4 Pages) Artesyn Technologies – 3W Wide Input DC/DC Converters
Embedded Power for
Business-Critical Continuity
Specifications Contd.
Rev.03.07.07
bxa3
3 of 4
INPUT
VOLTAGE
9-18 Vdc
9-18 Vdc
18-36 Vdc
18-36 Vdc
18-36 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
OUTPUT
VOLTAGE
3.3 V
15 V
3.3 V
5V
±5 V
3.3 V
5V
12 V
15 V
OUTPUT
CURRENT (1)
600 mA
200 mA
600 mA
500 mA
±250 mA
600 mA
500 mA
250 mA
200 mA
INPUT
CURRENT (2)
245 mA
335 mA
122 mA
140 mA
140 mA
61 mA
69 mA
83 mA
83 mA
TYPICAL
EFFICIENCY
68%
75%
68%
76%
76%
68%
76%
76%
76%
REGULATION
LINE (3)
LOAD (4)
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
MODEL
NUMBER (5,8,9)
BXA3-12S3V3J
BXA3-12S15J
BXA3-24S3V3J
BXA3-24S05J
BXA3-24D05J
BXA3-48S3V3J
BXA3-48S05J
BXA3-48S12J
BXA3-48S15J
Notes
1 Maximum.
2 Maximum figure at full load (nominal).
3 Low line to high line.
4 Full load to no load.
5 An optional internal filter is available. When the filter is added, the BXA3
will meet VDE0871-A, VDE0878-A and EN55022-A. Add the suffix ‘-F’ to
the model number, e.g. BXA3-12S15-FJ.
6 Conducted noise filtering to EN55022 level B may be accomplished by
putting the following capacitors across the input pins.
12 Vdc
5 μF ceramic X7R dielectric type
24 Vdc
3 μF ceramic X7R dielectric type
48 Vdc
1 μF ceramic X7R dielectric type
7 Reverse voltage protection can be implemented by putting a fast blow fuse
on the positive input rail. Rate the fuse for 250 mA at 48 Vdc input, 500 mA
at 24 Vdc input and 1000 mA at 12 Vdc input.
8 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
9 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.