English
Language : 

BXA3 Datasheet, PDF (2/4 Pages) Artesyn Technologies – 3W Wide Input DC/DC Converters
Embedded Power for
Business-Critical Continuity
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Rev.03.07.07
bxa3
2 of 4
OUTPUT SPECIFICATIONS
Voltage accuracy
±1.0%
Line regulation
LL to HL, all outputs
±2.5%
Load regulation
Full load to no load
±2.5%
Ripple and noise
(5 Hz to 20 MHz)
+5 V output
All others
60 mV pk-pk, max.,
15 mV rms
100 mV pk-pk, max.,
15 mV rms
Temperature coefficient
±0.02%/°C, max.
Over voltage protection Clamp diode
135% Vout
Short circuit protection
Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range
12 Vdc
24 Vdc
48 Vdc
9-18 Vdc
18-36 Vdc
36-75 Vdc
Input filter
Suffix ‘-F’ (See Note 5)
Pi type
Reverse voltage
(See Note 7)
Yes
protection
Max. input rise
and fall time
Output remains within
specification
5 V/ms
EMC CHARACTERISTICS
Conducted emissions
EN55022, FCC part 15
Suffix ‘-F’ versions
(See Notes 5 and 6)
Level A
GENERAL SPECIFICATIONS
Efficiency
See table
Isolation voltage
Input/output
500 Vdc
Switching frequency
Variable
200 kHz to1 MHz
Approvals and
standards
VDE0805, EN60950, IEC950
UL1950, CSA C22.2 No. 950
Case material
Non-conductive
black plastic
Material flammability
UL94V-0 min.
Weight
15 g (0.53 oz)
MTBF
MIL-HDBK-217F
800,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
(See derating curve)
Non-operating amb
Cooling
-25 °C to +105 °C
-40 °C to +105 °C
Free air convection
cooled
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non operating
10,000 feet max.
40,000 feet max.
Vibration
5 Hz to 500 Hz
2.5 G rms (approx.)