8000A Datasheet, PDF (9/19 Pages) Emcore Corporation – System 8000 Fiber-Optic Interfacility Links | |||
|
◁ |
Data Sheet, Rev. 0
March 6, 2003
System 8000 Fiber-Optic Interfacility Links
C-Band, Extended C-Band, X-Band, and Ku-Band Interfacility Link Specifications
(continued)
Typical X-Band Performance (continued)
Table 11. X-Band Interfacility Link Specifications: 8850A Tx and 8860A Rx
Parameter
Specification
Symbol Min
Typ
Max
Unit
Passband
â
7.25
â
8.40
GHz
Optical Loss Budget
LOPT
â
6
Nominal RF Input at Max Input Gain
RFIN
â
â30
Link Gain (â6 dB with Redundancy Switching)
G
â9
â
â
dB
â
dBm
11
dB
Flatness
Gain Slope
Gain Stability at Constant Temperature
Noise Figure at Max Input Gain
(Add 4 dB with Redundancy Switching)
Spur-Free Dynamic Range*
â
â
âGT
NF
SDFR
â
±0.25 /48
â
dB/MHz
â
±0.75/500
â
dB/MHz
â
â¤0.02
â
dB/MHz
â
±0.15/24
â
dB/hr
â
26
â
dB
â
92
â
dB/Hz2/3
Group Delay:
Peak-to-Peak
Linear
Parabolic
Input/Output Impedance
Input/Output VSWR
â
â
0.5
â
ns
â
0.02
â
ns/MHz
â
0.01
â
ns/MHz2
Z
â
50
â
â¦
â
â
1.35:1
â
â
RF Connector
â
N Jack
â
Optical Fiber
Optical Connector
â
1310 nm, single mode
â
â
FC/APC (Tight-fit Keying),
â
Return Loss > 60
dB
Absolute Maximum RF Input (Max Input Gain)
RFIN MAX
â
â
â15
dBm
* Spur-free dynamic range (SFDR) = 2/3(IP3 â NF + 173.8) dB/Hz2/3; IP3 = input third-order intercept, NF = noise figure. SFDR is the range
where the carrier is above the noise and the third IM is below the noise, C/I = 2x(IP3 â PIN), where PIN = input RF/carrier for two carriers.
ORTEL a Division of EMCORE
9
|
▷ |