English
Language : 

MA3690 Datasheet, PDF (18/41 Pages) Dynex Semiconductor – 1553B Bus Controller/Remote Terminal
MA3690/1/3
Symbol Description
Min.
Typ.
Max.
Units
t40
RESETN ↓ to ADEN ↓
t41
PUCN ↑ to RESETN ↑
t42
RESETN ↑ to ADENN ↑
t43
Initialisation word set-up wrt RESETN ↑
15
t44
Initialisation word HOLD wrt RESETN ↑
20
t45
Minimum RESETN pulse width
90
t46
Minimum CK12 high
33
t47
Minimum CK12 low
20
t48
CK12 ↑ to CK4 ↑
t49
CK12 ↓ to CK4 ↓
t50
HALTREQN pulse width
1t
t51
HALTREQN ↑ to HALTEDN ↑
t52
HALTREQN ↑ to CODENN ↓
1t
t53
CODENN ↑ to CODENN ↓
t54
RT-RT minimum validation time
1) RT1 = 0 RT0 = 0
55.75
2) RT1 = 0 RT0 = 1
61 75
3) RT1 = 1 RT0 = 0
83.75
4) RT1 = 1 RT0 = 1
147.75
t55
HALTREQN setup for next message wrt to INCMDN ↑
t56
R/WN ↓
to R/WN ↓ RT-BC Report cycle
t57
BUFENN ↑ to BUFENN ↓ Data word to report word
t58
BC intermessage gap
1) without a No Operation instruction
2) with a No Operation instruction
t59
CODENN interval high between received status
and report word during report cycle
t60
CODENN interval between report word and
next message fetch for continuous operation
t61
CODEN interval between BC Noop data
pointer fetch and report word
t62
INCMDN ↑ to INCADDRN ↓
t63
BUSYREQN ↓ to BUSYACKN ↓
t64
BUSYREQN ↑ to BUSYACKN ↑
t65
INCMDN ↑ to BUSYACKN ↓
t66
INCMDN ↑ to BUSYACKN ↑
t67
CK4 ↑ to R/WN/BUFENN/CO/C1/CODENN/MDTN
80
nS
2t
2t
2t + 80
nS
nS
nS
nS
nS
nS
90
nS
90
nS
55
nS
2t
2t
56.25
uS
62.25
uS
84.25
uS
148.25
uS
150
nS
80t
29t
20
uS
28
uS
24t
6t
5t
1t
60
nS
60
nS
60
nS
100
nS
115
nS
Mil-Std-883, method 5005, subgroups 9, 10, 11
Notes:
1. t = CK4 period, t12 = CK12 period
2. Times quoted as typical means a fixed number of CK4 clock cycles but excludes slight variations due to
propagation delays.
Conditions: Vdd = 4.5 to 5.5V, Tamb = -55°C to +125°C, VIL = 0V, VIH = 4V, VOUT Threshold = 1.5V except t2 where measured
by a 1V change in output voltage. Load = 50pf except t2 where additional 1K load to 0V or VDD.
Figure 12: AC Electrical Characteristics (continued)
18/41