English
Language : 

AP91352 Datasheet, PDF (3/12 Pages) Diodes Incorporated – SAS DISABLE plus 5V eFUSE WITH INTEGRATED ISOFET
Functional Block Diagram
AP91352
Absolute Maximum Ratings (Note 4) (@ TA = +25°C, unless otherwise specified.)
Symbol
VCC
EN/FAULT
SAS
VOUT
ESD HBM
ESD CDM
TA(max)
TJ(max)
TST
PD
RθJA
Parameter
Input Voltage
Steady State
Transient (100ms)
Enable Voltage
SAS Disable Voltage
VOUT Voltage
Human Body ESD Protection JESD22-A114
Charged Device Model ESD Protection JESD22-C101
Maximum Ambient Temperature
Maximum Junction Temperature
Storage Temperature
Power Dissipation (TA = +25°C)
W-QFN3020-12
Thermal Resistance, Junction to Ambient (0.5 sq in) W-QFN3020-12 (Note 5)
Ratings
-0.3 to 12
-0.3 to 15
-0.3 to 6
-0.3 to 3.6
-0.3 to 7.0
2000
1000
-40 to +125
+150
-65 to +150
1.3
40
Units
V
V
V
V
V
V
°C
°C
°C
W
°C/W
Notes:
4. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
5. For a device surface mounted on 25mm by 25mm by 1.6mm FR4 PCB with high coverage of single sided 2oz copper, in still air conditions; the device is
measured when operating in a steady state condition.
Recommended Operating Conditions (All specifications are for -10°C < TA < +85°C, VCC = 5V, unless otherwise noted.)
Symbol
VCC
TA
Parameter
Input Voltage Range
Operating Ambient Temperature
Min
Typ
Max
Units
3.6
–
12
V
-40
–
+85
°C
AP91352
Document number: DS38109 Rev. 1 - 2
3 of 12
www.diodes.com
October 2015
© Diodes Incorporated