English
Language : 

HBGCMP Datasheet, PDF (5/8 Pages) Dialight Corporation – DuroSite® Series LED High Bay
DuroSite® Series LED High Bay Fixture
Ordering Information
Part
Number1,4
HBGCMP
HBGC4P
HB2C4P
HB0C4P
HB1C4N
HB6C4M
HB1C4J
HB2C4M
HB5C4M
HB5C4T
HB2C4K
HB7C4M
HB5C4J
HB1C4S
HB3C4L
HBWC4L
HB4C4L
HBGCQZ
HBGC1T
HB1C4T
HB6C4T
HB1C4S
HB5C4S
HB2C4T
HB7C1T
HB3C4R
HBGCMZ
HBGC4Z
HB1C4Y
HB6C4Y
HB5C4Y
HB7C4Y
HB2C4Y
HB2C4X
HB3C4W
HB4C4W
HBGCQQ
HBGC1Q
HB1C4H
HB2C1H
Initial
Fixture
Lumens2
17,500
14,500
12,000
11,500
11,500
11,500
11,000
10,750
10,750
10,750
10,500
10,500
10,500
10,500
9,000
8,750
8,500
17,500
14,500
11,500
11,500
11,000
10,500
10,500
10,250
9,000
17,500
14,500
11,500
11,500
10,750
10,500
10,250
10,000
9,000
8,500
17,500
14,500
11,500
10,250
Wattage
172
161
153
153
146
146
146
146
146
146
146
146
137
137
124
135
124
172
161
146
146
146
137
146
146
124
172
161
146
146
146
146
146
137
124
124
172
161
146
146
Lumens
Per Watt
UL-1598A
IP-66, NEMA - 4X
CSA 22.2 #250
Marine Wet Locations3
Lens5
Clear
Diffused
101
•
Tempered Glass
90
•
Tempered Glass
78
•
Polycarbonate
75
•
Polycarbonate
79
Acrylic
79
Acrylic
76
Acrylic
73
•
Polycarbonate
74
Acrylic
74
Acrylic
73
•
Polycarbonate
72
•
Polycarbonate
77
Acrylic
77
Acrylic
72
Acrylic
65
•
Polycarbonate
69
•
Polycarbonate
Occupancy Sensor High Bays
101
•
Tempered Glass
90
•
Tempered Glass
79
Acrylic
78
Acrylic
76
Acrylic
77
Acrylic
73
•
Polycarbonate
72
•
Polycarbonate
72
Acrylic
Variable Dimming High Bays
101
•
Tempered Glass
90
Tempered Glass
79
Acrylic
78
Acrylic
74
Acrylic
72
•
Polycarbonate
70
•
Polycarbonate
73
•
Polycarbonate
72
Acrylic
69
•
Polycarbonate
STEP Dimming / Occupancy Sensor High Bay
101
•
Tempered Glass
90
•
Tempered Glass
79
Acrylic
Variable Dimming / Occupancy Sensor High Bay
70
•
Polycarbonate
Optical Pattern
Circular Aisle
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Notes for all versions:
1 Part numbers listed in the above table are cool white. For neutral white version replace the 4th character with N Ex: HB1C4N become HB1N4N.
2 Initial fixture lumens based on temperatures up to 113°F (45°C).
3 Units meet IP-66 when installed using conduit or an IP66 approved cable gland at the 3/4 NPT. Dialight offers IP-66 approved cable glands as part
of accessories HBXW2 and HBXCG.
Notes for standard versions only:
4 Part numbers listed in the table above are 100-277V AC. For 347-480V AC version replace the 5th character with a 5. EX: HB1C4N (100-277VAC)
becomes HB1C5N (347-480V AC). For 17,500lm, 347-480V AC versions replace 5th character becomes a T. EX: HBGCMP (100- 277V AC) becomes
HBGCTP (347-480V AC).
5 Part numbers listed in the tables above come with a flat lens. For models with polycarbonate flat lens they can be ordered with a polycarbonate
dome lens; replace 3rd character with a L Ex: HB2C4M becomes HBLC4M .
www.dialight.com
5