TECHNICAL DATASHEET
PMC Panel Mount Power Supply
24V 75W 1 Phase / PMC-24V075W1A□
Functions
Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.
Hold-up Time
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 95% of its set value, after the input voltage is removed.
 Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
Inrush Current
Inrush current is the peak, instantaneous, input current
measured and, occurs when the input voltage is first applied.
For AC input voltages, the maximum peak value of inrush
current will occur during the first half cycle of the applied AC
voltage. This peak value decreases exponentially during
subsequent cycles of AC voltage.
Dynamic Response
The power supply output voltage will remains within ±5% of its
steady state value, when subjected to a dynamic load from 0%
to 100% of its rated current.
9
All parameters are specified at 25°C ambient unless otherwise noted.