24V 75W 1 Phase / PMC-24V075W1A□
Installation of Mounting Accessories
 Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep
a safety distance between the screw and internal components.
 Recommended mounting tightening torque: 4~8Kgf.cm.
Safety Instructions
– To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm from all ventilated surfaces while the device
is in operation.
– The device is not recommended to be placed on low thermal conductive surface, for example, plastics.
– Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply.
Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
– Do not touch the terminals while power is being supplied. Risk of electric shock.
– Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause:
Electric shock; Safety Hazard; Fire; Product failure
– Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device,
remove L and N connections before removing the Earth connection.