English
Language : 

Q48SA52001NNFA Datasheet, PDF (8/12 Pages) Delta Electronics, Inc. – Delphi Series Q48SA, 60W Quarter Brick Family DC/DC Power Modules: 36~75V in, 52V/1.15A out
FEATURES DESCRIPTIONS
Over-Current Protection
The modules include an internal output over-current
protection circuit, which will endure current limiting for
an unlimited duration during output overload. If the
output current exceeds the OCP set point, the modules
will automatically shut down (hiccup mode).
The modules will try to restart after shutdown. If the
overload condition still exists, the module will shut down
again. This restart trial will continue until the overload
condition is corrected.
Over-Voltage Protection
The modules include an internal output over-voltage
protection circuit, which monitors the voltage on the
output terminals. If this voltage exceeds the over-voltage
set point, the module will shut down and latch off. The
over-voltage latch is reset by either cycling the input
power or by toggling the on/off signal for one second.
Also, an option of hiccup mode for OVP is available.
Under hiccup mode, the modules will try to restart after
shutdown. If the over voltage condition still exists, the
module will shut down again. This restart trial will
continue until the over voltage condition is corrected.
Over-Temperature Protection
The over-temperature protection consists of circuitry
that provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold
the module will shut down.
The module will try to restart after shutdown. If the
over-temperature condition still exists during restart, the
module will shut down again. This restart trial will
continue until the temperature is within specification.
Remote On/Off
The remote on/off feature on the module can be either
negative or positive logic. Negative logic turns the
module on during a logic low and off during a logic high.
Positive logic turns the modules on during a logic high
and off during a logic low.
Remote on/off can be controlled by an external switch
between the on/off terminal and the Vi(-) terminal. The
switch can be an open collector or open drain.
For negative logic if the remote on/off feature is not
used, please short the on/off pin to Vi(-). For positive
logic if the remote on/off feature is not used, please
leave the on/off pin to floating.
Figure 15: Remote on/off implementation
Output Voltage Adjustment (TRIM)
To increase or decrease the output voltage set point,
the modules may be connected with an external
resistor between the TRIM pin and either Vo(+) or
Vo(-).The TRIM pin should be left open if this feature is
not used.
Figure 16: Circuit configuration for trim-up (increase output
voltage)
If the external resistor is connected between the TRIM
and Vo(-) pin, the output voltage set point increases
(Fig. 17). The external resistor value required value
required to obtain output voltage change △U is defined
as:
Rtrim −up
=
127.5
ΔU
− 4.7(KΩ)
Ex. When Trim-up 5%,△U is
5%*Vnormal=0.05*52.5=2.625
Rtrim−up
=
127 .5
2.625
− 4.7
=
43.87 KΩ
DS_Q48SA52001_05142009
8