DESIGN CONSIDERATIONS
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules and
affect the stability. A low ac-impedance input source is
recommended. If the source inductance is more than a
few µH, we advise adding a 10 to 100 µF electrolytic
capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the
input of the module to improve the stability.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate in
a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB layout
issues, please contact Delta’s technical support team. An
external input filter module is available for easier EMC
compliance design..below is the reference design for an
input filter tested with E36SR12005 to meet class B .
With filter, Cin=100uF/100V, Cy=1.5nF
L=0.53mH .
Test Result:vin=48V,Io=5A.
dBµV
80.0
Cx=2.2uF
70.0
Limits
55022MQP
55022MAV
60.0
50.0
40.0
Transducer
LISNPUL
30.0
Traces
PK+
AV
20.0
10.0
0.0
150 kHz
1 MHz
10 MHz
30 MHz
Blue line is peak mode, green is average mode.
DS_E36SR12005_09162013
Safety Considerations
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950-1, CSA
C22.2 NO. 60950-1 2nd and IEC 60950-1 2nd : 2005 and
EN 60950-1 2nd: 2006+A11+A1: 2010, if the system in
which the power module is to be used must meet safety
agency requirements.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2 or
SELV. An additional evaluation is needed if the source
is other than TNV-2 or SELV.
When the input source is SELV circuit, the power module
meets SELV (safety extra-low voltage) requirements. If
the input source is a hazardous voltage which is greater
than 75 Vdc and less than or equal to 75 Vdc, for the
module’s output to meet SELV requirements, all of the
following must be met:
The input source must be insulated from the ac mains by
reinforced or double insulation.
Š The input terminals of the module are not operator
accessible.
Š A SELV reliability test is conducted on the system
where the module is used in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
When installed into a Class II equipment (without
grounding), spacing consideration should be given to the
end-use installation, as the spacing between the module
and mounting surface have not been evaluated.
The power module has extra-low voltage (SELV) outputs
when all inputs are SELV.
This power module is not internally fused. To achieve
optimum safety and system protection, an input line fuse
is highly recommended. The safety agencies require a
normal-blow fuse with 10A maximum rating to be
installed in the ungrounded lead. A lower rated fuse can
be used based on the maximum inrush transient energy
and maximum input current.
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes electrical
testing. Inadequate cleaning and/or drying may lower the
reliability of a power module and severely affect the
finished circuit board assembly test. Adequate cleaning
and/ordrying are especially important for un-encapsulated
and/or open frame type power modules. For assistance
on appropriate soldering and cleaning procedures, please
contact Delta’s technical support team.