English
Language : 

FHS-A9015S00 Datasheet, PDF (59/78 Pages) Delta Electronics, Inc. – Thermal performance for 45 W CPU
Test Report.
ATTACHMENTS
No. SHAEC1515770519
Date: 13 Aug 2015 .
Page 4 of 5.
RoHS Testing Flow Chart
1) Name of the person who made testing: Bob Zhang/Gary Xu/Zengzhen Zhu/Sunny Qin
2) Name of the person in charge of testing: Jan Shi/Summer Jin/Jessy Huang/Stone Chen
3) These samples were dissolved totally by pre-conditioning method according to below flow chart.
(Cr6+ and PBBs/PBDEs test method excluded)
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Filtration
Solution
Residue
1) Alkali Fusion /
Dry Ashing
2) Acid to dissolve
ICP-OES/AAS
DATA
PBBs/PBDEs
Sample solvent
extraction
Concentration/
Dilution of extraction
solution
Nonmetallic
material
Adding digestion
reagent
Filtration
GC/MS
DATA
Heating to 90~95℃
for extraction
Filtration and pH
adjustment
Adding 1,5-
diphenylcarbazide
for color
development
UV-Vis
DATA
Cr6+
Metallic
material
Positive
Spot test
Negative
Boiling water
extraction
Adding 1,5-
diphenylcarbazide
for color
development
A red color
indicates the
presence of Cr6+.
If necessary,
confirm with UV-
Vis.
DATA