English
Language : 

FHS-A9015S00 Datasheet, PDF (36/78 Pages) Delta Electronics, Inc. – Thermal performance for 45 W CPU
Test Report.
No. CANEC1503047702
Date: 13 Mar 2015 .
Page 8 of 13.
ATTACHMENTS
RoHS Testing Flow Chart
1) Name of the person who made testing: Bruce Xiao / Sunny Hu
2) Name of the person in charge of testing: Bella Wang / Cutey Yu
3) These samples were dissolved totally by pre -conditioning method according to below flow chart
(Cr6+ and PBBs/PBDEs test method excluded ).
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
PBBs/PBDEs
Sample solvent
extraction
Nonmetallic
material
Cr6+
Metallic
material
Filtration
Solution
Residue
Concentration/
Dilution of extraction
solution
Filtration
Adding digestion Positive
reagent
Spot test
Heating to
90~95℃ for
extraction
Negative
Boiling water
extraction
1) Alkali Fusion /
Dry Ashing
2) Acid to
dissolve
ICP-OES/AAS
DATA
GC-MS
DATA
Filtration and
pH adjustment
Adding 1,5-
diphenylcarbazide
for color
development
UV-Vis
Adding 1,5-
diphenylcarbazide
for color
development
A red color
indicates the
presence of Cr 6+. If
necessary , confirm
with UV-Vis.
DATA
DATA