PMF-24V240WCXX Datasheet, PDF (4/14 Pages) Delta Electronics, Inc. – Built-in Active PFC and fan speed control
TECHNICAL DATASHEET
PMF Panel Mount Power
24V 240W 1
/ PMF-24V240WC□□
Safety Standards / Directives
Safety Entry Low Voltage
Electrical Safety
CE
Material and Parts
Galvanic Isolation
TUV Bauart
UL/cUL recognized
CB scheme
CCC
Input to Output
Input to Ground
Output to Ground
SELV (EN 60950-1)
EN 60950-1
UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395)
CB scheme to IEC 60950-1
GB4943
In conformance with EMC Directive 2014/30/EU and
Low Voltage Directive 2014/35/EU
RoHS Directive 2011/65/EU Compliant
3.0KVac
2.0KVac
0.5KVac
EMC
Emissions (CE & RE)
Immunity
Electrostatic Discharge
Radiated Field
Electrical Fast Transient / Burst
Surge
Conducted
Power Frequency Magnetic Fields
Voltage Dips and Interruptions
Low Energy Pulse Test (Ring
Wave)
Harmonic Current Emission
Voltage Fluctuation and Flicker
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
CISPR 32, EN 55032, FCC Title 47: Class B
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
Level 4 Criteria A1)
Air Discharge: 15kV
Contact Discharge: 8kV
Level 3 Criteria A1)
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
Level 3 Criteria A1)
2kV
Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1kV
Level 3 Criteria A1)
150kHz-80MHz, 10Vrms
Criteria A1)
10A/Meter
IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable
IEC61000-4-12
Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1kV
IEC/EN 61000-3-2, Class A and Class D
IEC/EN 61000-3-3
4
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.