English
Language : 

PMF-24V240WCXX Datasheet, PDF (2/14 Pages) Delta Electronics, Inc. – Built-in Active PFC and fan speed control
TECHNICAL DATASHEET
PMF Panel Mount Power
24V 240W 1
/ PMF-24V240WC□□
Specifications
Input Ratings / Characteristics
Nominal Input Voltage
Input Voltage Range
Nominal Input Frequency
Input Frequency Range
Input Current
Efficiency at 100% Load
Max Inrush Current (Cold Start)
Power Factor at 100% Load
Leakage Current
100-240Vac
85-264Vac
50-60Hz
47-63Hz
< 3.60A @ 115Vac, < 1.80A @ 230Vac
87.0% typ. @ 230Vac
< 35A @ 115Vac, < 60A @ 230Vac
> 0.99 typ. @ 115Vac, > 0.95 typ. @ 230Vac
< 0.6mA @ 240Vac
Output Ratings / Characteristics*
Nominal Output Voltage
Factory Set Point Tolerance
Output Voltage Adjustment Range
Output Current
Output Power
Line Regulation
Load Regulation
PARD** (20MHz)
Rise Time
Start-up Time
Hold-up Time
Dynamic Response
(Overshoot & Undershoot O/P Voltage)
Start-up with Capacitive Loads
Remote ON/OFF Function (Option)
24Vdc
24Vdc ± 1% (initial set point tolerance from factory)
21.6-26.4Vdc
10.0A (240W max.)
240W
± 0.5% typ. (@ 115Vac & 230Vac)
± 0.5% typ. (@ 115Vac & 230Vac)
< 150mVpp @ 25°C
< 300mVpp @ -10°C
50ms typ. @ 115Vac & 230Vac (100% load)
1200ms typ. @ 115Vac & 230Vac (100% load)
20ms typ. @ 115Vac & 230Vac (100% load)
± 5% (2.4V pk-pk) @ 115Vac & 230Vac (0-100% load)
CN102
8,000µF Max
Output ON: 5-12.5V
Output OFF: 0-0.5V
(For more information, please refer to the details in the
Functional Manual section on Page 10)
*For power de-rating from 50°C to 70°C, see power de-rating on page 3.
. **PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor
2
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2017, Rev. 01)