English
Language : 

DRS-24V30W1AZ Datasheet, PDF (4/11 Pages) Delta Electronics, Inc. – Sync DIN Rail Power Supply
TECHNICAL DATASHEET
Sync DIN Rail Power Supply
24V 30W 1 Phase (NEC Class 2) / DRS-24V30W1AZ
Safety Standards / Directives
Electrical Safety
Industrial Control Equipment
Class 2 Power Supply
CCC
CE
Material and Parts
Galvanic Isolation
EMC
EMC / Emissions
Immunity to
Electrostatic Discharge
Radiated Field
Electrical Fast Transient / Burst
Surge
Conducted
Power Frequency Magnetic Fields
Voltage Dips
Voltage Fluctuation and Flicker
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
TUV Bauart to EN 60950-1, UL/cUL recognized to
UL 60950-1, CSA C22.2 No. 60950-1
(File No. E131881), CB scheme to IEC 60950-1,
Limited Power Source (LPS)
UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01
(File No. E338991)
UL/cUL recognized to UL 60950-1, CSA C22.2
No. 60950-1
GB9254, GB17625.1 and GB4943.1
仅适用于海拔 2000m 以下地区安全使用
In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
Input to Output
Input to Ground
Output to Ground
RoHS Directive 2011/65/EU Compliant
3.0KVac
1.5KVac
0.5KVac
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
CISPR 22, EN 55022, EN 61000-6-3, EN 61000-6-4,
FCC Title 47: Class B
EN 55024
Level 3 Criteria A1)
Air Discharge: 8kV
Contact Discharge: 8kV
Level 2 Criteria A1)
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
Level 3 Criteria A1)
4kV
Level 4 Criteria A1)
Common Mode2): 4kV
Differential Mode3): 2kV
Level 3 Criteria A1)
150kHz-80MHz, 10Vrms
Criteria A1)
1A/Meter
> 100% dip; 1 cycle (20ms)
IEC/EN 61000-3-3
4
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (March 2015, Rev. 00)