English
Language : 

DRP024V120W1AA_14 Datasheet, PDF (4/13 Pages) Delta Electronics, Inc. – CliQ DIN Rail Power Supply
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
24V 120W 1 Phase / DRP024V120W1AA
Safety Standards / Directives
Electrical Equipment in Power Installations
Electrical Safety
Industrial Control Equipment
Hazardous Location / ATEX
II 3G ATEX 94/9/EC;
IECEx test report
CE
Material and Parts
Galvanic Isolation
EN 50178 / IEC 62103
SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1
and CSA C22.2 No. 60950-1, CSA to CSA C22.2 No.
60950-1 and UL 60950-1, CB scheme to IEC 60950-1
UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01,
CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
cCSAus to CSA C22.2 No. 213-M1987 and ANSI / ISA
12.12.01:2007
Class I, Division 2, Group A, B, C, D T4, Ta= -20°C to
+80°C (> +50°C derating)
Input to Output
Input to Ground
Output to Ground
EN 60079-0:2009, EN 60079-15:2010 ( II 3G Ex nA
IIC T4 Gc, Ta= -20°C to +80°C (> +50°C derating))
Certificate No. EPS 09 ATEX 1 215 X;
For IEC 60079-0, IEC 60079-15
In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
RoHS Directive 2011/65/EU Compliant
4.0KVac
1.5KVac
1.5KVac
EMC
EMC / Emissions
Immunity to
Electrostatic Discharge
Radiated Field
Electrical Fast Transient / Burst
Surge
Conducted
Power Frequency Magnetic Fields
Voltage Dips
Low Energy Pulse Test (Ring Wave)
Harmonic Current Emission
Voltage Fluctuation and Flicker
Voltage Sag Immunity
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-12
CISPR 22, EN 55022, EN 55011, FCC Title 47: Class B
EN 55024, EN 61000-6-1
Level 4 Criteria A1)
Air Discharge: 15kV
Contact Discharge: 8kV
Level 3 Criteria A1)
80MHz-1GHz, 10V/M, 80% modulation (1kHz)
Level 3 Criteria A1)
2kV
Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 2kV
Level 3 Criteria A1)
150kHz-80MHz, 10Vrms
Criteria A1)
100A/Meter
100% dip; 1 cycle (20ms); Self Recoverable
Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1Kv
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3
SEMI F47 - 0706, at 130Vac
4
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (May 2014, Rev. 03)