English
Language : 

DRP024V120W1AA_14 Datasheet, PDF (3/13 Pages) Delta Electronics, Inc. – CliQ DIN Rail Power Supply
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
24V 120W 1 Phase / DRP024V120W1AA
Mechanical
Case Cover / Chassis
Dimensions (L x W x D)
Unit Weight
Indicator
Cooling System
Terminal
Wire
Mounting Rail
Noise (1 Meter from power supply)
Environment
Surrounding Air Temperature
Power De-rating
Operating Humidity
Operating Altitude
Shock Test (Non-Operating)
Vibration (Non-Operating)
Pollution Degree
Protections
Overvoltage
Overload / Overcurrent
Over Temperature
Short Circuit
Protection Against Shock
*PE: Primary Earth
Reliability Data
MTBF
Expected Cap Life Time
Input
Output
Aluminium
121 x 50 x 118.7 mm
0.54 kg
Green LED (DC OK)
Convection
3 Pins (Rated 300V/20A)
2 Pins (Rated 300V/20A)
AWG 22-14
Standard TS35 DIN Rail in accordance with EN 60715
Sound Pressure Level (SPL) < 40dBA
Operating
Storage
Vertical Mounting
-20°C to +80°C
-25°C to +85°C
> 50°C de-rate power by 2.5% / °C
5 to 95% RH (Non-Condensing)
0 to 2,000 Meters
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,
3 times per direction, 18 times in total
IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak);
90 min per axis for all X, Y, Z direction
2
32V ±10%, SELV Output, Hiccup Mode,
Non-Latching (Auto-Recovery)
> 150% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery)
< 80°C Surrounding Air Temperature @ 100% load,
Non-Latching (Auto-Recovery)
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Class I with PE* connection
> 500,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C
10 years (115Vac & 230Vac, 50% load @ 40°C)
3
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (May 2014, Rev. 03)