English
Language : 

DRP024V060W3BA Datasheet, PDF (4/14 Pages) Delta Electronics, Inc. – CliQ II DIN Rail Power Supply
TECHNICAL DATASHEET
CliQ II DIN Rail Power Supply
24V 60W 3 Phase / DRP024V060W3B□
Reliability Data
MTBF
Expected Cap Life Time
> 800,000 hrs. as per Telcordia SR-332
I/P: 3 x 400Vac, O/P: 100% load, Ta: 25°C
10 years (3 x 400Vac & 3 x 500Vac, 50% load @ 40°C)
Safety Standards / Directives
Electrical Equipment in Power Installations
Electrical Safety
Industrial Control Equipment
Hazardous Location / ATEX (For DRP024V060W3BA)
EN 50178 / IEC 62103
SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1
and CSA C22.2 No. 60950-1, CB scheme to
IEC 60950-1
UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01,
CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA
12.12.01:2007 [Class I, Division 2, Group A, B, C, D T4,
Ta = -25°C to +80°C (Vertical: > +50°C derating,
Horizontal: > +45°C derating)]
II 3G ATEX 94/9/EC (For DRP024V060W3BA)
CE
EN 60079-0:2012, EN 60079-15:2010 [ II 3G Ex nA
IIC T4 Gc, Ta= -25°C to +80°C (Vertical: > +50°C
derating, Horizontal: > +45°C derating)]
Certificate No. EPS 13 ATEX 1 575 X
In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
Material and Parts
Galvanic Isolation
Input to Output
Input to Ground
Output to Ground
For DRP024V060W3BA:
In conformance with Equipment for explosive
atmospheres (ATEX) directive 94/9/EC
RoHS Directive 2011/65/EU Compliant
4.0KVac
2.0KVac
1.5KVac
4
All parameters are specified at 25°C ambient unless otherwise indicated.