English
Language : 

PMC-24V300W1BA Datasheet, PDF (3/14 Pages) Delta Electronics, Inc. – 24V 300W 1 Phase
Panel Mount Power Supply
Technical Information
PMC-24V300W1BA
5.) Environmental
Ambient temperature (Operating)
Ambient temperature (Storage)
Humidity Operation
Shock Test (in all directions)
Vibration (in all X,Y,Z direction)
(Non-Operating)
Bump
MTBF
Expected Life Time
RoHS Compliant
Altitude (Operating)
Degree of protection
Class of protection
Pollution degree
Climatic class
-20°C to +50°C, with operation to 70°C possible with a linear derating to
50% of nominal power from 50°C.
-25°C to 85°C
< 95% RH non-condensing
30G (300m/S2) according to IEC60068-2-27
10 to 150Hz @ 50m/S2 (5G peak) according to IEC 60068-2-6.
Note: all figures quoted are amplitudes (peak values).
IEC/EN 60068-2-29; 11ms/ 10gn
> 700,000 Hours.
10 years.
Yes, RoHS directive, WEEE directive
@ 3,000 Meters
IP20
Class I with PE connection
2
3K3 according to EN 60721
5.) Mechanical Data
Dimensio n
Cooling System
Input Terminal & Output Terminal
Mounting Rail
Connection
Input wire size
Output wire size
Indicator
Type of housing
Weight
199 mm X 105 mm X 41 mm (L X W X H)
Fan Cooling (Built-in DC Fan)
Terminal Block 7 pin (300VAC, 20A)
Standard T35 Mounting Rail (35mm) EN60715
Screw Terminal
AWG 20-16
AWG 20-16
Green LED “DC OK” LED (Same LED will Flicker upon fault)
Aluminium
0.820Kg
6.) Certification/Safety Standards
EMI : Immunity to interference according to EN 61000-6-2
 EN 61000-4-2 1)
Discharge of static electricity (ESD): LEVEL 4
Air Discharge/Contact discharge: 15 KV / 8 KV
 EN 61000-4-3 1)
Housing: LEVEL 3
Radiate Field Immunity
 EN 61000-4-4 1)
 IEC 61000-4-5 1)
Frequency/Field intensity:
Fast transients (Burst Immunity):
Surge voltage Immunity:
Common Mode/Differential Mode:
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation.
LEVEL 3 / 2KV4)
LEVEL 3
2 KV3) / 1 KV4)
 EN 61000-4-6 1)
I/O: LEVEL 3
Conducted Immunity
 EN 61000-4-8 1)
 EN 61000-4-11 2)
Frequency / Uo:
Power frequency magnetic field:
Voltage dips:
0.15MHz - 80MHz / 10Vrms.
LEVEL 3 : 10A/Meter
100% dip, Input: Main Buffering > 20ms.Self Recoverable
EMC : Noise emission according to EN 61000-6-3
 Emitted radio interface
 Radio interference voltage
FCC Title 47, Class B / EN55022, CISPR22, CISPR11, CLASS B5
FCC Title 47, Class B / EN55022, CISPR22, CISPR11, CLASS B5
Galvanic Isolation :
Input / output
type test/routine test : 3KVAC
Input / PE
type test/routine test : 1.5KVAC
output / PE
type test/routine test : 0.5KVAC
Electrical equipment of machines
EN60950-1 and IEC60204-1(With overvoltage category III)
Electronic equipment for use in electrical power Installations
EN50178 and IEC62103
Safety entry low voltage
PELV (EN60204), SELV (EN60950)
Electrical Safety for Information technology equipment
UR/cUR recognize to UL60950-1 and CSA C22.2 No.60950-1,SIQ,CCC
Electrical Safety for Industrial Control Equipment
CB test certificate and report to IEC60950-1/EN60950-1
CE (EMC and Low Voltage directive)
Protection against electric shock
DIN 57100-410
Conformance with EMC guideline 2004/108/EC
Compliant with following standards :
and for low voltage guideline 2006/95/EC :
IEC60950-1/EN60950-1 : 2006/95/EC (Low Voltage Directive)
EN55011 Class B
: 2004/108/EC (EMC Directive)
EN55022 Class B
EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EN 61000 corresponds to IEC 61000
1) Criterion A: Normal operating behavior within the defined limits.
2) Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
3) Symmetrical: Conductor to conductor.
4) Asymmetrical: Conductor to ground.
5) Class B:
Area of application industry and residential.
3/3
3/21/2011
Rev: 01,