English
Language : 

MDS-065APS15-B Datasheet, PDF (3/10 Pages) Delta Electronics, Inc. – MDS Medical AC-DC Open Frame
T``E`CHNICAL DATASHEET
MDS Medical AC-DC Open Frame
15Volt, 63Watt / MDS-065APS15 B
(a) 115V
Fig. 2 Ripple & Noise example, 20MHz BW
(b) 230V
Ripple & Noise measurement circuit
PSU
5cm
0.47uF Ceramic
10uF Electrolytic
Load
Scope
Test Fixture
Mechanical
Dimensions(W x L x H)
Weight (typ.)
Terminal
Environment
Surrounding Air Temperature
Power De-rating
Operating Humidity
Operating Altitude
Shock Test (Non-Operating)
Vibration (Operating)
Input
Output
Operating
Storage
50.8 x 101.6 x 30.0 mm(2 x 4 x 1.2 in)
130 grams (4.6 Ounces)
JST 2P
JST 4P
-10°C to +70°C
-40°C to +85°C
-10°C to +50°C 100% load
50°C to 70°C de-rate power by 2.5% / °C, See Fig. 3
10-95% RH (Non-Condensing)
3,000 meters (9842.52 feet)
50G, 11ms, 3 shocks for each direction
5-500Hz, 2.09Grms, 20 minute for each three axis
3
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (November 2016, Rev. 04)