English
Language : 

DRP024V120W1BA Datasheet, PDF (3/12 Pages) Delta Electronics, Inc. – CliQ II DIN Rail Power Supply
TECHNICAL DATASHEET
CliQ II DIN Rail Power Supply
24V 120W 1 Phase / DRP024V120W1B□
Mechanical
Case Cover
Dimensions (L x W x D)
Unit Weight
Indicator
Cooling System
Terminal
Wire
Mounting Rail
Environment
Surrounding Air Temperature
Power De-rating
Operating Humidity
Operating Altitude
Shock Test (Non-Operating)
Vibration (Non-Operating)
Bump
Pollution Degree
Protections
Overvoltage
Overload / Overcurrent
Over Temperature
Short Circuit
Degree of Protection
Protection Against Shock
*PE: Primary Earth
Reliability Data
MTBF
Expected Cap Life Time
Aluminium
121 x 50 x 123.1 mm
0.37 kg
Green LED (DC OK)
Convection
Input Pluggable Connector 3 Pins (Rated 300V/15A)
Output Pluggable Connector 4 Pins (Rated 300V/15A)
Input AWG 20-12
Output AWG 20-12
Standard TS35 DIN Rail in accordance with EN60715
Operating
Storage
-20°C to +85°C
-25°C to +85°C
> 50°C de-rate power by 2.5% / °C
< 95% RH (Non-Condensing)
2,500 Meters
IEC60068-2-27, 30G (300m/S²) for a duration of 18ms
IEC60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak);
60 min per axis for all X, Y, Z direction
IEC60068-2-29; 11ms / 10gn
2
<32V +10%, SELV Output, Hicc-up Mode,
Non-Latching (Auto-Recovery)
> 150% of rated load current, Hicc-up Mode,
Non-Latching (Auto-Recovery)
< 80°C Surrounding Air Temperature @ 100% load,
Non-Latching (Auto-Recovery)
Hicc-up Mode, Non-Latching
(Auto-Recovery when the fault is removed)
IP20
Class I without PE* connection
> 800,000 hrs. as per Telcordia SR-332
10 years (115Vac & 230Vac, 50% load @ 40°C)
3
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (September 2013, Rev. 03)