English
Language : 

AA04S0300A Datasheet, PDF (3/5 Pages) Delta Electronics, Inc. – 4W Single and Dual Output, AC/DC Power Module
Environmental Specifications
Parameter
Temperature Range (operational)
Ambient
Storage Temperature Range
Over Temperature Protection
Cooling
Humidity (non condensing)
Power Derating Curve
100
80
Conditions
-25℃
-40℃
at 90℃ (automatic recovery at 67℃)
Free-Air convection
---
+60℃
+85℃
95 % rel. H
60
40
20
0
~
-25
10
20
30
40
50
60
Ambient Temperature C
Notes
1 All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless
otherwise noted.
2 Ripple & Noise measurement bandwidth is 0~20 MHz
3 These power modules require a minimum output loading to maintain specified regulation, operation under no-load conditions will not
damage the power supplies however they may not meet all listed specifications.
4 All AC/DC modules should be externally fused at the front end for protection.
5 Other input and output voltage may be available, please contact us for custom solution .
6 Specifications are subject to change without notice
DS_AA04S/D_04082014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc P3