English
Language : 

AA04S0300A Datasheet, PDF (2/5 Pages) Delta Electronics, Inc. – 4W Single and Dual Output, AC/DC Power Module
Output Characteristics
Parameter
Conditions
Min.
Typ.
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Minimum Load
Single and Dual Output Models
---
±1.0
ABF-04D53 & ABF-04D125
---
±2.0
Single and Dual Output Models
---
±0.5
Vo1
---
±0.5
ABF-04D53 & ABF-04D125
Vo2
---
±1.0
3.3VDC Output Model
---
±1.0
5~24VDC and Dual Output Models
---
±0.5
Vo1
---
±0.5
ABF-04D53 & ABF-04D125
Vo2
---
±2.5
3.3V & 5VDC Output Models
---
100
Other Output Models
---
0.8
Single Output and Dual +/- Output Models No min. Load
---
required
Dual +/+ Output Models
---
25
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
Zener diode clamp
---
120
---
±0.01
---
---
Foldback, auto-recovery
(long term overload condition may cause
105
---
damage)
Hiccup mode, indefinite (automatic recovery)
Max.
±2.0
±5.0
±1.0
±1.0
±3.0
±1.5
±1.0
±1.0
±5.0
150
1.0
---
---
---
±0.02
5
---
Unit
%
%
%
%
%
%
%
%
%
mV P-P
%VPP of Vo
%Inom.
%Inom.
% of Vo
%/℃
%Vout
%Inom.
General Characteristics
Parameter
Conditions
I/O Isolation Voltage
Input to Output, 60 Seconds
I/O Isolation Resistance
500 VDC
Switching Frequency
Hold-up Time
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
EMC Emission
Conducted and radiated
Standard
EN61000-4-2
EN61000-4-3
EMC Immunity according
EN61000-6-1
EN61000-4-4
EN61000-4-5
EN61000-4-6
Protection Class II
Safety Approvals
EN61000-4-8
EN61000-4-11
Min.
Typ.
Max.
Unit
3000
---
---
VAC
100
---
---
MΩ
---
130
---
KHz
---
20
---
ms
330,000
---
---
Hours
EN 55011 class B, EN 55022 class B, FCC part 15 class B
Specification Requirement
Performance
Criteria
Air ±8KV Cont. ±4KV
B
80~1000MHz, 10V/m 80% AM, 1KHz modulation
A
AC port ±2KV DC, SL, TL ±2KV not less than 1
B
min.
1.2/50μS(8/20μS) AC dif. ±1KV DC ±0.5KV
B
0.15~80MHz, 10Vrms (functional earth ports
included)
B
80% AM, 1KHz modulation
50Hz/60Hz, 30A/m
A
30%, 10ms
B
60%, 100ms, 95%, 5000ms
C
According IEC/EN 60536
cUL/UL 60950-1,IEC/EN 60950-1
Recommended Input Fuse
External Fuse (Recommended)
All Models
1A Slow – Blow Type
DS_AA04S/D_04082014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc P2