English
Language : 

Q48SC12050 Datasheet, PDF (20/26 Pages) Delta Electronics, Inc. – 600W DC/DC Power Modules
OPERATION [0x01]
Bit number
Purpose
Bit Value
Meaning
7:
Enable/Disable the module
1
0
6:
Reserved
5:4
Margins
00
01
10
3:0
Reserved
VOUT_OV_FAULT_RESPONSE [0x41]
Output is enabled
Output is disabled
No margin
Margin low(Act on Fault)
Margin high(Act on Fault)
Bit number
Purpose
Bit Value
Meaning
7:6
Response settings
5:3
Retry setting
2:0
Delay time setting
10
Unit shuts down and responds according to the
retry settings
111
Unit continuously restarts while fault is present
until commanded off
000
Unit does not attempt to restart on fault
000
No delay supported
Default
Settings,
0x80
1
0
00
0000
Default
Settings,
0xB8
10
111
000
IOUT_OC_FAULT_RESPONSE [0x47]
Bit number
Purpose
7:6
Response settings
5:3
Retry settings
2:0
Delay time setting
Bit Value
11
111
000
000
Meaning
Default
Settings, 0xF8
Unit shuts down and responds according to the
11,
retry settings
Unit continuously restarts while fault is present
111
until commanded off
Unit does not attempt to restart on fault
No delay supported
000
OT_FAULT_RESPONSE [0x50]
Bit number
Purpose
7:6
Response settings
5:3
Retry settings
2:0
Delay time setting
Bit Value
10
111
000
000
Meaning
Default
Settings,0xB8
Unit shuts down and responds according to the
10
retry settings
Unit continuously restarts while fault is present
111
until commanded off
Unit does not attempt to restart on fault
No delay supported
000
DS_Q48SC12050_03312017
E-mail: dcdc@deltaww.com
http://www.deltaww.com/dcdc
P20