IMA-x400 Power Supply Series
Curves
IMA-x400-12
Tested at 90 Vac input
Output power [W]
400
290
200
100
0
40 50 60 70
Ambient temperature [°C]
Airflow > 0.8 m/s
Natural convection
Fig. 7: Output power versus ambient temperature 12 V
IMA-x400-xx
Output power [%]
100
90
IMA-x400-24/48
Tested at 90 Vac input
Output power [W]
400
300
200
100
0
40 55 70
Ambient temperature [°C]
Airflow > 0.8 m/s
Natural Convection
Fig. 8: Output power versus ambient temperature 24/48 V
IMA-x400-12
Output current [A]
33.3
27.8
80 90
275
Input voltage [Vac]
Fig. 9: Output power versus input voltage
IMA-x400-24
Output current [A]
16.7
13.9
9.6
12
14.4
Output voltage [Vdc]
Fig. 10: Output current versus output voltage 12 V
IMA-x400-48
Output current [A]
8.33
7.14
19.2
24
28.8
Output voltage [Vdc]
Fig. 11: Output current versus output voltage 24 V
38.4
48
56
Output voltage [Vdc]
Fig. 12: Output current versus output voltage 48 V
10