English
Language : 

ES235 Datasheet, PDF (33/37 Pages) Cyrustek corporation – 4000 Counts DMM / Peak
ES235
4000 Counts DMM / Peak
5.2. LCD Display On Condition
LCD Annunciator
Condition
V
In voltage measurement mode, and diode measurement mode.
A
In current measurement mode.
Ω
In resistance measurement mode, and continuity mode.
F
In capacitance measurement mode.
In continuity check mode.
In diode mode.
%
In duty cycle measurement.
Hz
In frequency mode.
ADP1
When ADP1 mode is active.
ADP2
When ADP2 mode is active.
ADP3
When ADP3 mode is active.
ADP4
When ADP4 mode is active.
DC
In DC voltage or DC current mode.
AC
In AC voltage or AC current mode.
AUTO
When automatic full scale range selection is enabled.
MANU
In manual mode.
HOLD
When HOLD function is enabled.
When Relative function is enabled.
MAX
When MAX function is enabled.
MIN
When MIN function is enabled.
PMAX
When PEAK function is enabled and show maximum value.
PMIN
When PEAK function is enabled and show minimum value.
SCAN
When smart (resistance, continuity, diode, capacitance auto check mode) is active.
m1
In capacitor measurement mode and the full scale range is in the order of mF.
µ1
In capacitor measurement mode and the full scale range is in the order of uF.
n
In capacitor measurement mode and the full scale range is in the order of nF.
m2
In voltage or current measurement mode and the full scale range is in the order of 10-3.
µ2
In current measurement mode and the full scale range id in the order of uA.
M
In resistance measurement mode and the full scale range is in the order of MΩ.
K
In resistance measurement mode and the full scale range is in the order of KΩ.
℃
In temperature measurement mode and when the unit is℃ .
℉
In temperature measurement mode and when the unit is℉ .
When the reading is exceeding default hazardous live voltage or OL in DCV or ACV,
the HV warning symbol will be display.
APO
When auto power off function is enabled.
SLB1
When voltage (ref. to V-) of LBAT9 pin is less than Vt1, SLB1 will disappear.
SLB2
When voltage (ref. to V-) of LBAT9 pin is less than Vt2, SLB2 will disappear.
SLB3
When SLB2 disappears for 8 seconds, SLB3 will be blinking.
RS232
When RS232 output is enabled.
When LED measurement function is enabled.
TEST
V 2.2