ES235 Datasheet, PDF (29/37 Pages) Cyrustek corporation – 4000 Counts DMM / Peak
ES235
4000 Counts DMM / Peak
4.1. RANGE
This packet indicates range state of the meter. The M_DP1 – M_DP3 corresponding DP1 – DP3 of
LCD segment (see section 5). In DCV 4.000V range, this a03 packet will set xxxx001x. If change to
40.00V the packet will be xxxx010x.
D0
D1
D2
D3
D4
D5
D6
D7
a03
X
X
X
X
M_DP1 M_DP2 M_DP3
X
4.2. Main_Digit1 –Main_Digit3
Main_Digit1 – Main_Digit3 is the readings of measurement result shown on LCD panel. DigitN3 –
DigitN0 consist of 4-bit BCD code. The M_SIGN is the sign bit of readings.
D0
a04 M_SIGN
a05 Digit33
a06 Digit13
D1
X
Digit32
Digit12
D2
X
Digit31
Digit11
D3
X
Digit30
Digit10
D4
X
Digit23
Digit03
D5
X
Digit22
Digit02
D6
X
Digit21
Digit01
D7
X
Digit20
Digit00
4.3. FUNCTION
The packets of a07-a09 indicate the measurement mode of the meter. The following table
summarizes the transmitted bit for each mode. Note that the encoding of this packet is different from
the encoding of FC1-FC5 switch.
For example, if the meter operates in Voltage mode, this a07 packet is 10000000. If VAHZ key is
pushed to VAHZ mode, the a08 will be 10000000 also.
D0
a07
V
a08 VAHZ
a09 ADP0
D1
A
℃
ADP1
D2
Ohm
℉
ADP2
D3
Continuity
X
ADP3
D4
Diode
EFmode
X
D5
Capacitance
SCAN
X
D6
Hz
Clamp
X
D7
Duty
LED
X
4.4. STATUS
The a10-a13 packets indicate the whole status when ES235 is in normal operation. For example, if
meter is operated at ACV / MANU range, then a10 packet will set 011000xx.
The format of the four packets are shown below.
D0
a10 AUTO
a11 SLB3
a12 REL
a13 Danger
D1
MANU
SLB2
ZERO
OPEN
D2
AC
SLB1
MAX
SHORT
D3
DC
LBAT30s
MIN
DISCH
D4
OL
BW_full
CURRENT
X
D5
UL
X
PHCAL
X
D6
X
BW1K
PMAX
X
D7
X
HOLD
PMIN
X
V 2.2
29
2015/12/15