Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Supply Voltage to Ground Potential .................−0.5V to +7.0V
DC Input Voltage ......................................... −0.5V to VDD +0.5V
Storage Temperature ....................................... −65°C to +150°C
Max soldering temperature (10 sec) ............................ 260°C
Junction temperature ................................................... 125°C
Operating Conditions
Parameter
VDD
TA
CL
Description
Supply Voltage
Ambient Operating Temperature
Load Capacitance
Package power dissipation..................................525 mWatts
Operating Range
Ambient
Temperature
0°C ϖ TAMBIENT ϖ 70°C
VDD & AVDD
5V ± 5%
Min.
4.75
0
Max.
Unit
5.25
V
70
°C
25
pF
Electrical Characteristics Over the Operating Range
Parameter
VOH
VOL
VIH
VIL
IIH
IIL
IOZ
IDD
Description
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input HIGH Current
Input LOW Current
Output Leakage Current
Power Supply Current
Test Conditions
IOH = −4.0mA
IOL = 4.0 mA
Except XTALIN pins
Except XTALIN pins
VIN = 5.25V
VIN = 0V
Three-state outputs
VDD = VDD max., 100 MHz, VIN = VDD or 0V
Min.
2.4
2.0
15
Max.
0.4
0.8
150
−250
10
100
Unit
V
V
V
V
µA
µA
µA
mA
5