CY14C101I_13 Datasheet, PDF (30/42 Pages) Cypress Semiconductor – 1-Mbit (128 K x 8) Serial (I2C) nvSRAM with Real Time Clock
CY14C101I
CY14B101I
CY14E101I
DC Electrical Characteristics (continued)
Over the Operating Range
Parameter
Description
Test Conditions
VIH
VIL
VOL
Rin[11]
Vhys
VCAP[12]
VVCAP[13, 14]
Input HIGH voltage
Input LOW voltage
Output LOW voltage
Input resistance (WP, A2, A1)
Hysteresis of Schmitt trigger
inputs
Storage capacitor
IOL= 3 mA
IOL= 6 mA
For VIN = VIL (Max)
For VIN = VIH (Min)
Between VCAP pin
and VSS
Maximum voltage driven on VCAP VCC = Max
pin by the device
CY14C101I
CY14B101I
CY14E101I
CY14C101I
CY14B101I
CY14E101I
Min
0.7 VCC
– 0.5
0
0
50
1
0.05 VCC
170
42
–
–
Typ [9]
–
–
–
–
–
–
–
220
47
–
–
Max
VCC + 0.5
0.3 VCC
0.4
0.6
–
–
–
Unit
V
V
V
V
K
M
V
270
F
180
F
VCC
V
VCC– 0.5 V
Data Retention and Endurance
Over the Operating Range
Parameter
DATAR
NVC
Data retention
Nonvolatile STORE operations
Description
Min
20
1,000
Unit
Years
K
Thermal Resistance
Parameter [14]
Description
JA
Thermal resistance
(junction to ambient)
JC
Thermal resistance
(junction to case)
Test Conditions
Test conditions follow standard test methods and
procedures for measuring thermal impedance, according
to EIA / JESD51.
16-pin SOIC
56.68
32.11
Unit
C/W
C/W
Notes
11. The input pull-down circuit is stronger (50 K) when the input voltage is below VIL and weak (1 M) when the input voltage is above VIH.
12. Min VCAP value guarantees that there is a sufficient charge available to complete a successful AutoStore operation. Max VCAP value guarantees that the capacitor on
VCAP is charged to a minimum voltage during a Power-Up RECALL cycle so that an immediate power-down cycle can complete a successful AutoStore. Therefore it
is always recommended to use a capacitor within the specified min and max limits. Refer application note AN43593 for more details on VCAP options.
13. Maximum voltage on VCAP pin (VVCAP) is provided for guidance when choosing the VCAP capacitor. The voltage rating of the VCAP capacitor across the operating
temperature range should be higher than the VVCAP voltage.
14. These parameters are guaranteed by design and are not tested.
Document Number: 001-54391 Rev. *K
Page 30 of 42