Figure 30. Watchdog Timer Block Diagram
Oscillator
32.768 KHz
Clock
Divider
32 Hz
Counter
1 Hz
Zero
Compare
WDF
WDS
Load
Register
WDW
DQ
Q
write to
Watchdog
Register
Watchdog
Register
Programmable Square Wave Generator
The square wave generator block uses the crystal output to
generate a desired frequency on the INT pin of the device. The
output frequency can be programmed to be one of these:
1. 1Hz
2. 512 Hz
3. 4096 Hz
4. 32768 Hz
The square wave output is not generated while the device is
running on backup power.
Power Monitor
The CY14X512PA provides a power management scheme with
power fail interrupt capability. It also controls the internal switch
to backup power for the clock and protects the memory from low
VCC access. The power monitor is based on an internal band gap
reference circuit that compares the VCC voltage to VSWITCH
threshold.
As described in the section AutoStore Operation on page 4,
when VSWITCH is reached as VCC decays from power loss, a data
STORE operation is initiated from SRAM to the nonvolatile
elements, securing the last SRAM data state. Power is also
switched from VCC to the backup supply (battery or capacitor) to
operate the RTC oscillator.
When operating from the backup source, read and write
operations to nvSRAM are inhibited and the RTC functions are
not available to the user. The RTC clock continues to operate in
the background. The updated RTC time keeping registers are
available to the user after VCC is restored to the device (see
AutoStore or Power-Up RECALL on page 35).
Backup Power Monitor
The CY14X512PA provides a backup power monitoring system
which detects the backup power (either battery or capacitor
backup) failure. The backup power fail flag (BPF) is issued on
the next power-up in case of backup power failure. The BPF flag
is set in the event of backup voltage falling lower than VBAKFAIL.
The backup power is monitored even while the RTC is running
in backup mode. Low voltage detected during backup mode is
flagged through the BPF flag. BPF can hold the data only until a
defined low level of the back-up voltage (VDR).
Interrupts
The CY14X512PA has a flags register, interrupt register, and
Interrupt logic that can signal interrupt to the microcontroller.
There are three potential sources for interrupt: watchdog timer,
power monitor, and alarm timer. Each of these can be individually
enabled to drive the INT pin by appropriate setting in the interrupt
register (0x06). In addition, each has an associated flag bit in the
flags register (0x00) that the host processor uses to determine
the cause of the interrupt. The INT pin driver has two bits that
specify its behavior when an interrupt occurs.
An Interrupt is raised only if both a flag is raised by one of the
three sources and the respective interrupt enable bit in interrupts
register is enabled (set to ‘1’). After an interrupt source is active,
two programmable bits, H/L and P/L, determine the behavior of
the output pin driver on INT pin. These two bits are located in the
interrupt register and can be used to drive level or pulse mode
output from the INT pin. In pulse mode, the pulse width is
internally fixed at approximately 200 ms. This mode is intended
to reset a host microcontroller. In the level mode, the pin goes to
its active polarity until the flags register is read by the user. This
mode is used as an interrupt to a host microcontroller. The
control bits are summarized in the section Interrupt Register.
Interrupts are only generated while working on normal power and
are not triggered when system is running in backup power mode.
Note CY14X512PA generates valid interrupts only after the
Power-Up RECALL sequence is completed. All events on INT
pin must be ignored for tFA duration after powerup.
Interrupt Register
Watchdog Interrupt Enable (WIE): When set to ‘1’, the
watchdog timer drives the INT pin and an internal flag when a
watchdog time out occurs. When WIE is set to ‘0’, the watchdog
timer only affects the WDF flag in flags register.
Alarm Interrupt Enable (AIE): When set to ‘1’, the alarm match
drives the INT pin and an internal flag. When AIE is set to ‘0’, the
alarm match only affects the AF flag in flags register.
Power Fail Interrupt Enable (PFE): When set to ‘1’, the power
fail monitor drives the pin and an internal flag. When PFE is set
to ‘0’, the power fail monitor only affects the PF flag in flags
register.
Square Wave Enable (SQWE): When set to ‘1’, a square wave
of programmable frequency is generated on the INT pin. The
frequency is decided by the SQ1 and SQ0 bits of the interrupts
register. This bit is nonvolatile and survives power cycle. The
SQWE bit over rides all other interrupts. However, CAL bit will
take precedence over the square wave generator. This bit
defaults to ‘0’ from factory.