English
Language : 

ILTS Datasheet, PDF (2/2 Pages) Cynergy3 Co – Submersible Dual Level and Temperature Transmitter
ILTS series
Submersible Dual Level &Temperature Transmitter
Electrical Protection
Supply reverse polarity
No damage but also no function
Lightning protection
Internally fitted
Electromagnetic compatibility CE Compliant
Mechanical Stability
Shock
100g / 11ms
Vibration
10g RMS (20 - 2000Hz)
Temperatures & Thermal Effects
Media Temperature
-20ºC (Non-freezing) to +60ºC
Storage temperature
-20ºC to +70ºC
Compensated temperature range(level only)
20ºC±25ºC
Thermal Zero Shift (TZS) (level only)
<±0.02% /FS/ºC
Thermal Span Shift(TSS) (level only)
<-0.015% /ºC
Thermal Drift (temperature only)
1µA/ºC
Material Specifications
Housing
“O” ring seals
Diaphragm
Cable sheath material
Media wetted parts
sheath
Miscellaneous
Current Consumption
Weight
Installation position
Operational Life
316L Stainless Steel
Viton
316L Stainless Steel
PUR
Housing, “O” ring seal, diaphragm, cable
Level transmitter limits at 28mA
Temperature transmitter limits at 21.5mA
Transmitter: approx 300g inc. nose cone
Cable: 48g per meter
Any, small zero shift when tilted through 90º
> 100x 106 cycles
Part No
ILTS-G0100-003
ILTS-G0500-007
ILTS-G1000-015
Pressure Range
Cable Length
0-1mWG (0-39"WG) 3M
0-5mWG (0-197"WG) 7M
0-10mWG (0-394"WG) 15M
Mechanical Dimensions
Boot
PUR sheathed vented cable
195mm Nominal
Nose cone
25mm dia
ISO9001 C E R T I F I E D
www.cynergy3.com