English
Language : 

VQ-120B Datasheet, PDF (4/4 Pages) CUI INC – AC/DC Metal Enclosed
A CUI INC COMPANY
VQ-120 Series AC/DC Metal Enclosed
8"x 4"x 2.0", 88~132VAC, 120W, QUADRUPLE OUTPUT
NO
TEST ITEM
5 RIPPLE&NOISE
TEST CONDITION / SPECIFICATION
I/P:230VAC
O/P:FULL LOAD
SPEC:
A: V1:
V2:
V3:
V4:
B: V1:
V2:
V3:
V4:
C: V1:
V2:
V3:
V4:
80mV
120mV
80mV
120mV
80mV
150mV
80mV
150mV
80mV
120mV
180mV
120mV
RESULT
A: V1: 45mV
V2: 38mV
V3: 22mV
V4: 35mV
B: V1: 34mV
V2: 49mV
V3: 25mV
V4: 42mV
C: V1: 25mV
V2: 24mV
V3: 50mV
V4: 27mV
VERDICT
P
6 AC INPUT CURRENT
I/P:230VAC
O/P:FULL LOAD
SPEC:1.25A
C:1.233A
P
I/P:230VAC
SPEC:30A
7 MAX. INRUSH CURREN O/P: FULL LOAD
C:29.05A
P
I/P:230VAC
SPEC: -5%~+10%
8
O/P VOLTAGE
ADJ.RANGE
O/P:MIN. LOAD
A: 4.38V~5.82V
B: 4.43V~5.75V
P
C: 4.44V~5.79V
I/P:230VAC
SPEC:200mS
9 SET UP TIME
C: 13.6mS
P
O/P:FULL LOAD
10 HOLD UP TIME
I/P:230VAC
SPEC:20mS
C: 33.9mS
P
O/P:FULL LOAD
11 EFFICIENCY
I/P:230VAC
O/P:FULL LOAD
SPEC:
A:77%
B:76%
C:80%
A:80%
B:81%
C:83.11%
P
12
OVER LOAD
PROTECTION
I/P:230VAC
O/P:TESTING
SPEC:105%~135%
A:125.8%
B:122.4%
C:120%
P
I/P:230VAC
SPEC:5.75~6.75V
13
OVER VOLTAGE
PROTECTION
O/P:FULL LOAD
A : 6.21V
B : 6.58V
P
C : 6.2V
14
GROUND LEAKAGE
CURRENT
I/P:240VAC
SPEC: L-FG--<3.5mA
N-FG--<3.5mA
A: L-FG:1.01mA
N-FG:1.07mA
P
15
INSULATION
RESISTANCE
SPEC: I/P-O/P: 500VDC/100M Ohms MIN.
C: O/P-FG >100M Ohms
I/P-FG: 500VDC/100M Ohms MIN.
I/P-O/P >100M Ohms
P
O/P-FG: 500VDC/100M Ohms MIN.
I/P-FG >100M Ohms
SPEC: I/P- O/P:
4.3KVDC/ 1 min.
DIELECTRIC /
16 WITHSTAND
VOLTAGE
(10mA CUT-OFF)
C: I/P-O/P :0.002mA
I/P - FG:
2.2KVDC/ 1 min.
(10mA CUT-OFF)
I/P-FG :0.002mA
P
O/P - FG:
0.75KVDC/ 1 min.
O/P-FG :0.002mA
(10mA CUT-OFF)
17 BURN-IN TEST
I/P: 230VAC O/P: FULL LOAD
C:NON BREAK
P
TA:24.7”C BURN-IN DURATION : 2 hrs
V-INFINITY LLC, 9615 SW Allen Blvd., Suite 103, Beaverton, OR 97005
1-866-372-1258
www.v-infinity.com