English
Language : 

D2410FPG-10 Datasheet, PDF (2/8 Pages) Crydom Inc., – Series 1 240 VAC
DatasPahneleMeoutnt
INPUT SPECIFICATIONS (5)
Description
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage
Must Turn-Off Voltage
Minimum Input Current [mA]
Maximum Input Current [mA]
Nominal Input Impedance [Ohms]
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
GENERAL SPECIFICATIONS (5)
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Housing Material
Baseplate Material
Input Terminal Screw Torque Range (in-lb/Nm)
Load Terminal Screw Torque Range (in-lb/Nm)
SSR Mounting Screw Torque Range (in-lb/Nm)
Input/Load Terminal Screw Torque Range (in-lb/Nm) (2)
Input/Output Terminal Screw Thread Size
Humidity per IEC60068-2-78
LED Input Status Indicator
MTBF (Mean Time Between Failures) at 40°C ambient temperature (11)
MTBF (Mean Time Between Failures) at 60°C ambient temperature (11)
D24xx
3-32 VDC
-32 VDC
3.0 VDC (9)
1.0 VDC
7
12
1/2 Cycle (10)
1/2 Cycle
A24xx
90-280 Vrms
-
90 Vrms
10 Vrms
5
10
Current Regulated
20
30
Parameters
4000 Vrms
109 Ohm
8 pF
-40 to 80 °C
-40 to 125 °C
2.6 oz (74.9g)
94 V-0
Aluminum
13-15 /1.5-1.7
18-20 / 2.0-2.2
18-20 / 2.0-2.2
w/”K” option 8-10 / 0.9-1.13
#6-32 UNC / #8-32 UNC
93% non-condensing
w/”G” option (green)
11,641,553 hours (1,328 years)
7,210,376 hours (823 years)
A24xxE
18-36 Vrms
-
18 Vrms
4 Vrms
16
20
20
30
WIRING DIAGRAM
AC
V
Load (12)
1( )
2( )
1
OUTPUT
2
SOLID STATE RELAY
4
INPUT
3
Terminals
Input
Output
Recommended Wire Sizes
Wire Size
(Solid / Stranded)
24 AWG (0.2 mm2) / 0.2 [minimum]
2 x 12 AWG (3.3 mm2) / 3.3 [maximum]
20 AWG (0.5 mm2) / 0.518 [minimum]
2 x 10 AWG (5.3 mm2) / 5.3
2 x 8 AWG (8.4 mm2) / 8.4 [maximum]
Wire Pull-Out
Strength (lb)[N]
10 [44.5]
90 [400]
30 [133]
110 [490]
90 [400]
Input Current vs Input Voltage
Standard Regulated DC Input
25
20
15
10
5
0
0
5
10
15
20
25
30
DC Input Voltage
4 (– / ) 3 (+ / )
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
Diagram: Series 1 AC control
AC 4
AC 3
AC/DC
Converter
Current
Limiter
(13)
Trigger
(14)
Circuit
1 AC
(15)
2 AC
Diagram: Series 1 DC control
-DC 4
(13)
Trigger
(14)
Circuit
+DC 3
Current
Limiter
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
1 AC
(15)
2 AC